Related Experiment Video
Updated: Mar 29, 2026

Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
The Agreement Between Pulse Oximetry and Measured Arterial Oxygen Saturations in Postoperative Functionally
Fabio Savorgnan1, Sebastian Acosta1, Joshua Prabhu2
1Department of Pediatrics, Division of Critical Care, Baylor College of Medicine, Houston, TX 77030, USA.
Abstract:
Background: Pulse oximetry is widely used to estimate arterial oxygen saturation, yet accuracy may vary for a number of reasons. Data on children with functionally univentricular circulation are limited. The primary aim of this study was to evaluate the agreement between arterial oxygen saturation measured by blood gas and pulse oximetry in children with functionally univentricular circulations. Methods: A retrospective analysis was performed of paired arterial blood gas and pulse oximetry oxygen saturation measurements following Norwood, Glenn, or Fontan procedures. Signed difference was defined as arterial oxygen saturation by blood gas-arterial oxygen saturation by pulse oximetry. Bland-Altman analyses, multivariable regressions, and generalized additive modeling were performed. Results: Mean bias was -4.9 percentage points, indicating pulse oximetry overestimated arterial saturation. The 95% limits of agreement were wide, from -20.7 to 10.8. The agreement was similar in Black and White patients. Fontan physiology demonstrated reduced overestimation by pulse oximetry by multivariable regression. Nonlinear modeling demonstrated more bias in agreement at lower arterial oxygen saturation levels, with arterial oxygen saturation levels explaining 50% of the variance. Conclusions: In functionally univentricular patients, pulse oximetry using the Nellcor MAXN-NS pulse oximeter (Medtronic, Dublin, Ireland) systematically overestimates arterial saturation, particularly in the setting of hypoxemia. Saturation level, rather than race, was the dominant determinant of bias.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...