Related Experiment Video
Updated: Mar 29, 2026

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound
Antonio Malvasi1, Giorgio Maria Baldini1, Tommaso Difonzo1
1Obstetrics and Gynecology Unit, Department of Interdisciplinary Medicine (DIM), University of Bari "Aldo Moro", 70124 Bari, Italy.
None:
Operative vaginal delivery (OVD) via vacuum extraction is a fundamental component of modern obstetric management, yet it carries specific risks of failure and maternal-fetal complications, such as cup detachment, cephalohematoma, and intracranial hemorrhage. The success and safety of the procedure rely heavily on the correct application of the vacuum cup over the "flexion point" of the fetal head. Traditional identification of this landmark via digital examination is often hindered by caput succedaneum and cranial molding, leading to high rates of diagnostic error, particularly in dystocic labor, due to fetal head malpositions and malpresentation. Intrapartum ultrasound (ITU) has demonstrated superior accuracy compared to clinical examination in assessing fetal head position and station and internal rotation. This expert commentary and technical proposal analyzes the current literature regarding vacuum extraction application and failures, focusing on the predictive value of ITU parameters (e.g., Angle of Progression, Midline Angle, Head-Symphysis Distance) and the impact of ITU on cup placement and delivery outcomes. Furthermore, we propose a novel technique: the "Ultrasound Flexion Point" (UFP). This method utilizes translabial ultrasound to identify the specific intersection of the fetal midline and the biparietal diameter as an objective sonographic proxy for the classical flexion point. By providing spatial orientation guidance immediately before the procedure, this technique aims to guide the operator in aligning the cup's notch with the sonographically identified target zone, using the midline angle as orientation reference, thereby potentially minimizing paramedian or deflexing applications and reducing the incidence of vacuum detachment and associated neonatal trauma. This expert commentary and technical proposal synthesizes current evidence and proposes a protocol requiring prospective validation through randomized controlled trials.
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Intrauterine Drug Delivery Systems

