Related Experiment Video
Updated: Mar 29, 2026

Dynamic Digital Biomarkers of Motor and Cognitive Function in Parkinson's Disease
Published on: July 24, 2019
Digital Recordings of Centric Relation Using Conventional and Digital Techniques: Patient-Reported Outcome Measures
Ece Selen Koçar1, Kıvanç Akça1
1Department of Prosthodontics, Faculty of Dentistry, Hacettepe University, 06230 Ankara, Türkiye.
Abstract:
Background/Objectives: Centric relation (CR) is a reproducible mandibular reference position that plays a critical role in complex prosthodontic cases. With the advent of digital jaw-tracking devices, CR can now be recorded with greater precision through fully digital methods. This study aimed to compare patient-reported outcome measures (PROMs) for the recording of CR determined with conventional and digital techniques. Methods: Patients requiring occlusal rehabilitation due to bilateral loss of posterior support in the maxilla were included. Two different jaw relation recording techniques were applied: conventionally determined CR and digitally determined CR. The former was determined using bimanual manipulation, while the latter through multiple mandibular closure recordings performed with an anterior plateau using a jaw-tracking device. PROMs were assessed using Visual Analog Scale (VAS) to evaluate patient experience during jaw relation recording and comfort during restoration try-in. The recording time for both techniques was documented, and the correlation between recording time and VAS scores related to the recording procedure was analyzed. Statistical analyses were performed using the Wilcoxon signed-rank test and Spearman correlation analysis (α = 0.05). Results: Twelve patients were included. No statistically significant difference was found between the two methods in VAS scores assessing patient-reported comfort and experience. Recording time was significantly shorter for the recording of conventionally determined CR (p = 0.002). No statistically significant correlation was found between recording time and patient-reported experience for both techniques (p > 0.05). Conclusions: Despite the need for clinician experience and patient compliance, PROMs for digitally determined CR were comparable to those of conventionally determined CR.
More Related Videos
Related Concept Videos
Methods of Documentation II: POMR
Methods of Documentation VII: EMR
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Data Reporting and Recording
Patient-centered Care
Pulse Assessment Sites

