Related Experiment Video
Updated: Mar 29, 2026

Establishment of a Robust and Reproducible Model of Radiation-Induced Skin and Muscle Fibrosis
Published on: August 31, 2022
Initial Evaluation of Feasibility and Cutaneous Toxicity of Electron FLASH Radiotherapy Using a Standard-of-Care
Elise Konradsson1, Kevin Liu1, Safee Baig1
1Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
Abstract:
Background/Objectives: FLASH radiotherapy (RT) has shown potential to reduce normal tissue toxicity compared with conventional (CONV) RT while maintaining tumor control. FLASH RT is characterized by ultra-high dose rate delivery, commonly using mean dose rates ≥ 40 Gy/s and sub-second delivery times. Most preclinical studies have used single-fraction regimens, leaving the feasibility and normal tissue impact of clinically relevant fractionation largely unexplored. We evaluated electron FLASH RT given in a standard five-fraction regimen to a porcine skin model, simulating adjuvant treatment workflow for high-risk cutaneous melanoma. Method: Three Yorkshire-Landrace swine received paired five-fraction electron irradiations to dorsolateral skin using either FLASH RT (mean dose rates 175-246 Gy/s) or CONV RT (8 Gy/min). Radiation was delivered with a 9-MeV electron beam; field diameters of 4, 7, or 10 cm; and doses of 5 × 6, 5 × 7, or 5 × 8 Gy. Dosimetry was validated with several dosimeters and real-time beam monitoring, confirming dose accuracy within 3%. Skin toxicity was assessed over 22-24 weeks using clinical grading, erythema spectrophotometry, and histopathologic evaluation. Results: FLASH RT was well tolerated at 5 × 6 Gy and 5 × 7 Gy, with no significant differences in peak radiation dermatitis, erythema index, or histologic damage compared with CONV RT. At 5 × 8 Gy, both modalities caused unacceptable toxicity, including moist desquamation and necrosis. No volume-dependent effects were observed. Conclusions: Although a FLASH-specific normal tissue sparing effect was not observed, this study demonstrates the technical feasibility and safety of delivering fractionated electron FLASH RT in a large animal model using a clinically relevant workflow. These findings support further investigation of physical beam parameters and biological modifiers, such as tissue oxygenation, and inform the clinical translation of fractionated FLASH RT for cutaneous malignancies.
More Related Videos
09:51One Minute, Sub-One-Watt Photothermal Tumor Ablation Using Porphysomes, Intrinsic Multifunctional Nanovesicles
Published on: September 17, 2013
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016