Semi-Supervised Graph Attention Network for Screw Pump Fault Diagnosis: Revealing the Dynamic Coupling of
Weigang Wen1, Jingqi Qin1, Qiuying Chang1
1School of Mechanical, Electronic and Control Engineering, Beijing Jiaotong University, Beijing 100044, China.
None:
The screw pump is a critical device for elevating downhole petroleum to the surface, and screw pump failure can significantly disrupt the production of oil wells. Due to the complex structure of the screw pump, the same pump fault can cause different changes in the monitoring parameters, and different faults can also cause the same parameter change. In consequence of the complexity, it requires a large amount of labeled data for a diagnosis model to achieve fault diagnosis of a screw pump in practical application. Aiming for this kind of condition, we discovered the dynamic coupling effect between multi-source information through detailed research on the collected data of screw pumps. To fully leverage the information dynamic coupling (IDC) effect, a semi-supervised learning graph attention network (SSL-GAT) fault diagnosis method is proposed. This approach integrates the semi-supervised learning framework and graph attention neural network for the fault diagnosis of a screw pump. The experimental validation of the SSL-GAT method demonstrates its outstanding performance in screw pump fault diagnosis.