Frequency-Direction Coupling in the Glass Transition Response of Thermally Aged Wet-Layup Unidirectional Carbon/Epoxy
Kruthika Kokku1, Rabina Acharya1, Vistasp M Karbhari1,2
1Department of Civil Engineering, University of Texas Arlington, Arlington, TX 76019, USA.
Abstract:
Dynamic mechanical thermal analysis (DMTA) is widely used to assess the effects of process- and environment-induced changes in polymer matrix composites, with the glass transition temperature (Tg) often reported from the tan d peak at a single excitation frequency. However, such an approach neglects the inherently kinetic nature of the glass transition and may obscure thermally induced changes in relaxation response. Multi-frequency DMTA was employed to investigate the evolution of glass transition response of a wet-layup unidirectional carbon/epoxy composite subjected to thermal aging at temperatures ranging from 66 °C to 260 °C for periods up to 72 h, using unexposed (23 °C) results as an ambient baseline reference. Tests were conducted using a single cantilever mode in both longitudinal and transverse configurations over a range of excitation frequencies from 0.3 to 30 Hz. Results demonstrate that thermal exposure affects not only the absolute value of the glass transition temperature, but also its frequency sensitivity and directional dependence. A frequency sensitivity parameter and a directional amplification factor are introduced to quantify frequency-direction coupling. While post-cure-dominated aging regimes exhibit relatively stable coupling behavior, degradation-dominated conditions at elevated temperatures and longer periods of thermal exposure lead to pronounced increases in transverse frequency sensitivity, which reflects early evolution of matrix- and interphase-level deterioration. These findings highlight the value of multi-frequency DMTA with tests in both primary directions for the mechanistic assessment of effects of thermo-oxidative response in polymer matrix composites.
Related Concept Videos
Fiber Reinforced Concrete
Accelerated Curing of Concrete
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Fatigue Strength of Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Effects of Air-entrainment in Concrete