Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Adaptive-Lag approach for assessing baroreflex functions: validation with the eurobavar dataset
Manish Goyal1, Arun Goel2, Narsingh Verma3
1All India Institute of Medical Sciences, Bhubaneswar, India. drmanishgoyal.aiims@gmail.com.
Abstract:
The arterial baroreflex is a fundamental short-term feedback mechanism stabilizing arterial pressure through autonomic modulation of heart rate and vascular tone. Conventional sequence method for Baroreflex sensitivity (BRS) assessment assumes a fixed delay between systolic pressure and cardiac interval responses, overlooking the physiological variability in reflex latency that arises from differences in neural conduction and effector kinetics. We developed and validated an Adaptive Lag (AL) Baroreflex Sensitivity method that accommodates variable delays, thereby quantifying both reflex gain and lag in response. Using 42 recordings from the EuroBaVar dataset, we compared the AL-BRS method (incorporating variable lags of 0-10 beats), to conventional sequence and spectral methods. The AL approach identified 34% more baroreflex sequences and demonstrated excellent agreement (r = 0.99) with fixed lag BRS. Also, Baroreflex Response Lag (BRL) was also determined which was significantly longer in subjects with impaired baroreflex function (supine: 2.35 vs. 1.16 beats). AL-BRS and BRL, showed superior diagnostic performance for identifying baroreflex impairment (AUC = 0.86 and 0.87, respectively), with BRL being excellent during standing (AUC = 0.95). These findings demonstrate that incorporating variable response time into BRS assessment not only refines sensitivity estimation but also reveals BRL as a temporal feature of baroreflex control, which carries diagnostic and potentially prognostic value in autonomic regulation. Thus AL-BRS method provides a more physiologically complete assessment of baroreflex function. This work advances the field by offering a refined, publicly available tool (implemented in MATLAB and R) for research and clinical applications.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: