Related Experiment Video
Updated: Mar 31, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Real-time energy measurement of clinical carbon ion beams using a cross-correlation time-of-flight method with
Na Hye Kwon1, Sung Woon Choi1, Soorim Han1
1Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
Background:
In carbon-ion radiotherapy (CIRT), the beam energy determines both the particle range and the overall dosimetric quality. Range-verification QA devices such as Zebra and Giraffe, which are based on multilayer ionization chambers (MLICs), can verify the range but only under dedicated QA conditions, leaving any energy deviations introduced by nozzle components undetected in real time. In particular, nozzle structures such as ridge filters can broaden or modulate the energy spectrum, causing the effective energy delivered to the patient to differ from the nominal accelerator setting. These limitations highlight the need for a real-time method capable of verifying the beam energy under actual clinical operating conditions.
Purpose:
We proposed a TOF-based beam-energy measurement concept that leverages a cross-correlation analysis of full detector waveforms. Compact and radiation-hard parallel-plate chambers (PPCs) were developed and evaluated, in contrast to prior TOF systems based on semiconductor detectors.
Methods:
PPCs (2.5 cm diameter active area, 0.4 mm gas gap) were operated in CO2. Two detectors were mounted coaxially with detector separations of 22.5 and 46.3 cm. Experiments were performed at Yonsei Heavy-ion Therapy Center (HITC) using four nominal energies (102.6, 140.4, 250.3, 430 MeV/nucleon) and three intensities, covering the clinically interesting ranges. Signals were digitized with a 1 GHz bandwidth oscilloscope. For each spill, paired waveforms were cross-correlated, and peak times were refined by parabolic interpolation to determine TOF. Precision and accuracy were evaluated across energies, intensities, and detector separations.
Results:
The PPCs operated stably for all beam conditions. Under pencil-beam delivery and normalized to 1 s acquisitions, the timing precision of the mean TOF (standard error) remained within 1 ps for both detector separations, scaling with (N: number of TOF samples per acquisition) and not representing the single-particle TOF resolution. Residuals between measured and theoretical TOF remained within 80 ps across energies and distances. After relativistic conversion from TOF to kinetic energy and then to water-equivalent range, all deviations were within a 1 mm range shift, meeting the recommended clinical criteria for range verification.
Conclusions:
We demonstrated that compact CO2-filled PPCs, operated as a TOF pair, can measure carbon-ion beam energy across the clinically relevant range of energies (≈100-430 MeV/u) and intensities used in routine treatment delivery. We achieved sub-picosecond timing precision on the TOF mean (standard error) per 1 s acquisition and submillimeter water-equivalent range accuracy using a robust cross-correlation analysis method. These results open the way to the integration of PPC-based TOF monitoring to tighten beam-delivery tolerances and improve the reliability and safety of carbon-ion radiotherapy.

