Identification of ticks from North of Italy by MALDI-TOF MS

Maria Sampieri1, Adama Zan Diarra2, Lionel Almeras3

  • 1Istituto Zooprofilattico Sperimentale della Lombardia e dell'Emilia Romagna (IZSLER), Brescia, Italy.

Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) has recently emerged as a promising method for arthropods identification. A total of 125 ticks collected from 2013 until 2023 in Italy either stored frozen at -20 °C (n = 75) or preserved in 70% ethanol (n = 50) were identified using morphological keys before being analyzed by MALDI-TOF MS and, when necessary, by molecular biology in Marseille, France. Of the 125 samples analyzed by MALDI-TOF MS, 106 (84.8%) yielded good quality MS spectra (i.e., intensity>3000 arbitrary units with low background noise). The spectra of 21 specimens from eight tick species, including Dermacentor marginatus, Haemaphysalis parva, Haemaphysalis punctata, Ixodes hexagonus, Ixodes ricinus, Rhipicephalus pusillus, Rhipicephalus sanguineus s.s., and Rhipicephalus turanicus whose morphological identities were confirmed by molecular methods, were used to update an in-house MALDI-TOF MS arthropod spectra database. Blind testing of the remaining 85 good quality spectra against the updated database produced the log score values (LSVs) ranging from 1.56 to 2.57. Overall, identification by MALDI-TOF MS matched morphological identification for 59/85 (69.4%) spectra, whereas 26/85 (30.6%) spectra were discordant with morphological identification. Molecular identification using 16S rRNA gene sequencing was available for 17/26 discordant samples, and 16/17 (94.1%) supported the MALDI-TOF MS result. Considering only samples confirmed by both MALDI-TOF MS and molecular methods, 71/72 (98.6%) were correctly identified by MALDI-TOF MS, with 68/72 (94.4%) showing LSVs > 1.8, a value previously reported as relevant for arthropod identification. This study confirms the effectiveness of MALDI-TOF MS for tick identification and highlights its potential as a new tool for tick identification in Italy.

Related Concept Videos

MALDI-TOF Mass Spectrometry01:19

MALDI-TOF Mass Spectrometry

Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...
7.5K
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.8K
Matrix-Assisted Laser Desorption Ionization (MALDI)01:08

Matrix-Assisted Laser Desorption Ionization (MALDI)

Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI is an ionization technique, widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix...
1.4K
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
3.0K