Related Experiment Video
Updated: Mar 31, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Interference of TiO2 in Fricke Dosimetry: Adsorption Mechanisms and Dose Measurement Challenges under Gamma
William Villacis1,2, Roque Santos1, María Natalia Piol2
1Escuela Politécnica Nacional, Facultad de Ingeniería Química y Agroindustria, Departamento de Ciencias Nucleares, Centro de Irradiación, Quito, Ecuador.
Abstract:
This review examines the interaction between Fricke dosimetry and TiO2 under gamma irradiation, highlighting the potential interference of TiO2 in standard dosimetric systems, particularly when this semiconductor is employed as a radiosensitizer (or, more accurately, a radiocatalyzer). The classical Fricke dosimetry, based on the radiolytic oxidation of Fe2+ to Fe3+, may be influenced by TiO2 through adsorption, therefore compromising dose accuracy. A recopilation of information on adsorption phenomena from both kinetic and equilibrium perspectives, applying classical and advanced models to characterize the retention of Fe2+ and Fe3+ on TiO2 surfaces, was performed. Particular attention is given to multicomponent systems that reflect the competitive nature of adsorption under Fricke conditions (acidic medium). We discuss how these interactions affect dosimetric responses, potentially leading to the underestimation of the radiation absorbed doses. Although the increasing use of TiO2 in radiocatalysis and advanced oxidation processes, standardized protocols for chemical dosimetry in such conditions are still missing. Research gaps include insufficient adsorption mechanistic studies, limited application of multicomponent models, and scarce integration of adsorption parameters into dosimetric assessments. Finally, methodological approaches to enhance dosimetric reliability in the presence of TiO2 were proposed, thereby contributing to the development of accurate and reproducible systems for several applications.
More Related Videos
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference