Related Experiment Video
Updated: Apr 2, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Effect of rotation axis and modulation on x-ray emission in dose assessment in panoramic radiographs using the Monte
Wilson Otto Batista1, Maria Rosangela Soares2, Jacqueline Machado Gurjão Rios1
1Department of Health Technology and Biology, Federal Institute of Bahia-Campus Salvador, Salvador, Bahia, Brazil.
Abstract:
This study investigates the impact of rotation axis configuration and modulation of tube voltage (kV) and dose rate on organ dose estimates in dental panoramic radiography, using Monte Carlo simulations. Computational phantoms representing 15 year-old male and female patients were each exposed to 16 protocol scenarios across three panoramic radiography units, varying the rotation centre (sliding versus fixed) and the presence or absence of x-ray beam modulation. Simulations were conducted using the particle and heavy-ion transport code system code, employing dump files and a multi-source approach to replicate realistic exposure conditions. Results were expressed and analysed as percentage differences relative to reference protocols incorporating a sliding rotation centre and beam modulation. The findings revealed a consistent and substantial underestimation-up to 50%-of doses to the thyroid, salivary glands, and brain when fixed-axis or non-modulated protocols were applied. The oral mucosa (lips and chin) exhibited marked overestimation (up to 700%), particularly in males, attributable to mandibular anatomy and beam geometry. Sex-related differences were evident in doses to the tongue and floor of the mouth, linked to anatomical mass variations, with male tongue mass approximately 8% greater than female. All results displayed relative errors below 5%. These findings highlight that simplified simulation models lacking a sliding rotation axis and beam modulation significantly distort and compromise dose assessments. Consequently, realistic modelling of beam dynamics is essential for accurate dosimetry in panoramic radiography.
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...