Related Experiment Video
Updated: Apr 2, 2026

Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025
An In Vitro Comparison of the Compression Resistance and Tear Strength of Interocclusal Recording Materials After
HimaBindu G1, Jhansi Muram1, Raja R N2
1Department of Prosthodontics, Chadalawada Krishna Srinivasa (CKS) Teja Institute of Dental Sciences and Researc, Tirupathi, IND.
Abstract:
Aim The purpose of the study is to evaluate the compression resistance and tear strength of interocclusal recording materials after immersion in a chemical disinfectant. Methods A total of 120 specimens were prepared, with 30 samples for each material type. These were further divided into two subgroups: a control group (no disinfection) and an experimental group (subjected to disinfection), with 15 specimens in each experimental group. The specimens in the experimental group were immersed in a commonly used chemical disinfectant, such as 2% glutaraldehyde for 30 min, while the control group was stored in a dry environment under ideal conditions without exposure to any disinfectant. The specimens were made into cylindrical and dumbbell shapes for compressive and tear strength testing, respectively, using a universal testing machine, and the values obtained were subjected to statistical analysis. Results The findings were analysed by ANOVA and Tukey's post hoc test in SPSS version 27.0 (IBM Inc., Armonk, New York). The results revealed that polyvinyl siloxane (PVS) exhibited the highest compression resistance and tear strength, both before and after disinfection, demonstrating superior mechanical stability. Aluwax showed moderate mechanical performance, with slight changes after immersion. In contrast, zinc oxide eugenol (ZOE) exhibited the lowest resistance, showing significant degradation in both properties post-immersion. Statistical analysis confirmed a significant impact of disinfection on material performance (p<0.05), particularly for ZOE. Conclusion Among the tested materials, PVS demonstrated the best overall performance, maintaining its mechanical integrity post-disinfection, making it the preferred choice for clinical applications requiring durability and accuracy. Aluwax retained moderate properties, while ZOE was the least reliable due to its significant degradation after immersion. These findings emphasize the need for careful material selection in prosthodontics to ensure clinical reliability while maintaining effective infection control.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Related Concept Videos
Chemical Agents for Microbial Control
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Hand hygiene
Hand washing...
Antimicrobial Effectiveness
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...