Related Experiment Video
Updated: Apr 2, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally
Preston Harrison1, Sarah Hall Kiriluk, Kevin Lee
1University of South Carolina School of Medicine Columbia, Columbia, SC (Harrison); Walter Reed National Military Medical Center, Bethesda, MD (Kiriluk), Prisma Health Radiology, Lexington, SC (Lee); Prisma Health Orthopedics, Lexington, SC (Mustafa, O'Keefe, Guirau, Jackson, Gonzalez); Columbia University Division of Orthopedics at Mount Sinai Medical Center, Miami Beach, FL (Vulcano); Hospital for Special Surgery, New York, NY (Johnson); Duke University Orthopedics, Durham, NC (Kaplan); Anderson Orthopaedic Clinic, Arlington, VA (Schipper).
Background:
Intraoperative fluoroscopy has become essential in orthopaedic surgery, particularly with the rise of minimally invasive surgery (MIS) techniques. As MIS techniques depend more on intraoperative imaging, MIS techniques may necessitate increased fluoroscopy use compared with open procedures. Despite the advantages of minimally invasive foot and ankle surgery, MIS techniques raise concerns about radiation exposure to both patients and surgical staff. The purpose of this study was to evaluate fluoroscopy time and radiation dose (cumulative air kerma) associated with open versus MIS bunion correction, comparing the open modified Lapidus procedure and the minimally invasive distal first metatarsal transverse osteotomy and akin osteotomy (META). It was hypothesized that the META procedure would be associated with increased radiation dose and fluoroscopy time compared with the open modified Lapidus procedure.
Methods:
A retrospective review was conducted for patients who underwent bunion surgery between January 2021 and June 2025 by two fellowship-trained orthopaedic foot and ankle surgeons at a single academic institution. A total of 294 patients met inclusion criteria. Of these, 258 patients underwent a META procedure and 36 underwent an open modified Lapidus procedure. Fluoroscopy time (minutes) and radiation dose (mGy) were compared between the groups.
Results:
A mean fluoroscopy time of 2.13 ± 1.27 (range, 0.06 to 7.05) minutes and a radiation dose of 2.02 ± 1.30 (range, 0.05 to 7.52) mGy were observed in the META cohort. An average fluoroscopy time of 1.63 ± 1.83 (range, 0.08 to 7.70) minutes and a radiation dose of 1.31 ± 1.43 (range, 0.07 to 5.98) mGy were observed in the open modified Lapidus cohort. Fluoroscopy time between the cohorts did not differ markedly ( P = 0.123); however, the META group demonstrated a higher radiation dose than the open modified Lapidus group ( P = 0.007).
Conclusion:
The META procedure had a markedly higher radiation dose compared with the open modified Lapidus procedure, although both remain substantially below the International Commission on Radiological Protection recommended occupational exposure of less than 20.00 mSv per year. Despite the META procedure generating an average radiation dose of 2.02 mGy per case, surgeons receive only 0.50% of the dose; thus, nearly 1,980 procedures would be required to exceed the 20.00 mSv annual occupational limit. These findings suggest that concerns about radiation exposure should not necessarily deter providers from performing the META technique for bunion correction.
Level Of Evidence:
III (Retrospective Comparative Study).
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
15:04An Anatomical Study of Nerves at Risk During Minimally Invasive Hallux Valgus Surgery
Published on: February 17, 2018
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Peripheral Artery Disease V: Postoperative Nursing Management