TRUE-MOGAD Score: A Novel Scoring System to Identify MOGAD Among Positive MOG-IgG Test Results
Andreu Vilaseca1, Angeliki G Filippatou2, Yana Said2
1Department of Neurology and Center for MS and Autoimmune Neurology, Mayo Clinic College of Medicine, Rochester, MN.
Objectives:
Myelin oligodendrocyte glycoprotein (MOG) antibodies (MOG-IgG) are a biomarker of MOG antibody-associated disease (MOGAD). However, false positives remain common. We aimed to develop a scoring tool to guide interpretation.
Methods:
Observational study of MOG-IgG-positive patients at Mayo Clinic (May 2022-December 2024). The primary outcome was fulfillment of 2023-MOGAD diagnostic criteria. Predictive variables were identified using logistic regression, and scoring systems were derived and evaluated using receiver operating characteristic analysis. Internal (n = 92) and external (Johns Hopkins, n = 117) validation was performed.
Results:
Of 215 MOG-IgG positive patients, 144 were true positive per 2023-MOGAD diagnostic criteria (positive predictive value, 67.0%). The TRUE-MOGAD score included: Titers (MOG-IgG clear positive [+1 point]), Relapsing optic neuritis (≥3 [+1 point]), Under 18 years at onset [+1 point], Encephalitis phenotype (ADEM or cerebral cortical encephalitis at onset [+2 points]), MRI or other supportive features from 2023-MOGAD-criteria [+2 points], Oligoclonal bands in CSF [-2 points], Gradually progressive or Abrupt onset [-2 points], and Disappearance ≥1 T2-lesion [+1 point]. The score showed an area under the curve (AUC) of 0.983 (95%CI 0.961-1.000). The score was validated internally (AUC = 0.976) and externally (AUC = 0.977).
Discussion:
The TRUE-MOGAD score is a practical tool that accurately identifies MOGAD among positive MOG-IgG test results and may guide diagnostic and therapeutic decisions in clinical practice.
Classification Of Evidence:
This study provides Class II evidence that a TRUE-MOGAD score of 2 or more accurately predicts MOGAD in patients with MOG-IgG titers of 1:20 or higher using the assay described.
More Related Videos
10:47Simple and Efficient Production and Purification of Mouse Myelin Oligodendrocyte Glycoprotein for Experimental Autoimmune Encephalomyelitis Studies
Published on: October 27, 2016
05:55Author Spotlight: Novel Assay for Studying B-Cell Responses in Multiple Sclerosis Research
Published on: December 1, 2023
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
McNemar's Test