Related Experiment Video
Updated: Apr 3, 2026

A Machine Learning Approach to Design an Efficient Selective Screening of Mild Cognitive Impairment
Published on: January 11, 2020
A Comprehensive Self-Medication Management System to Reduce Medication Errors Among People Living With Dementia:
Santosh Basapur1, Charles Gellman2, Jamie B Plenge3
1Department of Family and Preventive Medicine, Rush University Medical Center, Chicago, IL, United States.
The HiDO Home Care System (HCS) shows promise for improving medication adherence in people with dementia (PLwD). This AI-enabled device automates medication management, enhancing safety and reducing caregiver burden.
Area of Science:
- Gerontology and Geriatric Medicine
- Biomedical Engineering
- Artificial Intelligence in Healthcare
Background:
- Medication adherence is a significant challenge for people living with dementia (PLwD) and their caregivers.
- Current adherence tools often require manual interaction, lack clinical integration, and are unsuitable for individuals with cognitive decline.
- The HiDO Home Care System (HCS) is an AI-enabled self-medication device (SMD) designed to automate medication management.
Purpose of the Study:
- To evaluate the feasibility, usability, and performance of the HCS for at-home medication management in PLwD and caregiver dyads.
- To assess device setup, medication dispensing accuracy, task completion efficiency, and user satisfaction.
Main Methods:
- A pooled analysis usability study involving 35 caregiver-patient dyads at Rush University Medical Center.
- Participants completed device setup, automated medication dispensing, and simulated medication use with dual-camera verification.
- Quantitative measures included setup time, dispensing time, success rates, and System Usability Scale (SUS) scores; qualitative measures captured caregiver perceptions.
Main Results:
- All 35 dyads successfully completed dispensing tasks, with average first attempt times of 1:41 minutes.
- The HCS demonstrated consistent accuracy across users, achieving a mean SUS score of 70.2, indicating above-average usability.
- Caregivers reported potential stress reduction and suggested design improvements.
Conclusions:
- The HCS shows early feasibility, accuracy, and usability as an advanced SMD for PLwD, automating the medication safety chain.
- The device reduces caregiver workload and enhances patient safety and medication management.
- Further longitudinal studies are planned to assess clinical outcomes, caregiver burden, and cost-effectiveness.