Related Experiment Video
Updated: Apr 3, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Effects of High-Flow Nasal Cannula and Helmet Continuous Positive Airway Pressure in Acute Hypoxemic Respiratory
Silvia Coppola1, Mariarosa Pelliccia1, Tommaso Pozzi1,2
1Department of Anesthesia and Intensive Care, ASST Santi Paolo e Carlo, San Paolo University Hospital Milan, Milan, Italy.
Headings:
The effects of high-flow nasal cannula (HFNC) and continuous positive airway pressure (CPAP) in patients with acute hypoxemic respiratory failure (AHRF) on respiratory mechanics and inspiratory efforts are not entirely understood.
Objectives:
To compare the physiologic effects of HFNC and helmet CPAP with respect to conventional oxygen therapy (COT) in terms of respiratory mechanics, inspiratory effort, gas exchange, and hemodynamics during AHRF.
Design:
Crossover study.
Setting:
General surgical-medical ICU of San Paolo University Hospital, Milan, Italy.
Patients:
Thirty-three adult patients with AHRF, defined as an Pa o2 less than 60 mm Hg or an Pa o2 /F io2 less than 300 with a positive end-expiratory pressure (PEEP) level greater than or equal to 5 cm H 2 O, along with an Pa co2 less than 45 mm Hg.
Interventions:
After support with COT, three types of respiratory support were applied in random order: HFNC with 60 L/min of flow and helmet CPAP with 5 or 10 cm H 2 O of PEEP.
Measurements And Main Results:
Tidal volume, respiratory rate, inspiratory esophageal (ΔPes), and airway pressure swings were measured and an arterial blood gas analysis, along with hemodynamic data, was obtained after 20 minutes from the application of each respiratory support device. The application of HFNC and helmet CPAP at both 5 and 10 cm H 2 O of PEEP reduced minute ventilation (9.2 ± 3.2, 8.8 ± 2.3, and 9.3 ± 2.7 vs. 10.9 ± 3.3 L/min; p < 0.001) and ΔPes (-6.0 cm H 2 O [-7.8 to -4.0 cm H 2 O], -5.8 cm H 2 O [-7.2 to -4.5 cm H 2 O], and -5.9 cm H 2 O [-8.0 to -4.0 cm H 2 O] vs. -7.5 cm H 2 O [-10.8 to -6.5 cm H 2 O]; p < 0.001) while increasing Pa o2 /F io2 (188 ± 57, 208 ± 62, and 213 ± 69 vs. 129 ± 32; p < 0.001) with respect to COT; the application of 10 cm H 2 O of PEEP with helmet CPAP did not reduce inspiratory effort indices or increased oxygenation, but worsened mechanical power compared with HFNC and helmet CPAP with 5 cm H 2 O of PEEP.
Conclusions:
In patients with mild and moderate AHRF, HFNC and helmet CPAP ameliorated minute ventilation and respiratory rate, reduced inspiratory effort, and increased oxygenation compared with COT; the application of 10 cm H 2 O of PEEP during CPAP support worsened mechanical power.
More Related Videos
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...