Related Experiment Video
Updated: Apr 3, 2026

Multi-timescale Microscopy Methods for the Characterization of Fluorescently-labeled Microbubbles for Ultrasound-Triggered Drug Release
Published on: June 12, 2021
Towards reduced ultrasound localization microscopy acquisition times by uncoupling a bi-disperse microbubble
Giulia Tuccio1, Lisa Te Winkel2, Corinne Bruggeman2
1Department of Information Engineering and Computer Science, University of Trento, Trento, Italy.
Background:
Ultrasound Localization Microscopy (ULM) is a milestone in the medical vascular imaging context, enabling the precise characterization of micro-vascular structures using ultrasound imaging. By accurately localizing contrast microbubbles (MBs) flowing in the circulatory system, ULM generates micro-resolved vascular images, overcoming the ultrasonic diffraction limit. However, as ULM relies on precise localization and tracking of individual MBs, high MB concentrations yield to increased localization errors and, ultimately, ULM failure. This constraint limits ULM to low MB concentrations, resulting in long acquisition times that pose challenges in clinical settings. Methods: Here, we show the feasibility of uncoupling a bi-disperse MB population, composed of two monodisperse MB populations. The uncoupling is performed through a signal processing pipeline that exploits the strong nonlinear response of MBs having resonance frequency tuned with the transmission frequency. After uncoupling, ULM density and velocity flow maps are generated. Results: Density and velocity maps are generated after uncoupling, when injecting the bi-disperse population individually and simultaneously in a vascular 3D-printed phantom. Furthermore, density maps generated after uncoupling are compared with the one obtained using standard ULM. Results demonstrate the capability of the proposed uncoupling pipeline to separate the bi-disperse population. Conclusion: This work presents a signal processing pipeline to uncouple a bi-disperse MB population, formed by two monodisperse MB populations. Results are validated in a 3D-printed phantom and demonstrate the feasibility of the uncoupling which, in turn, would enable higher concentrations and reduce acquisition times for micro-vascular imaging.
More Related Videos
10:12Ultrasound Localization Microscopy for Super-Resolution Mapping of the Rodent Brain Microvasculature
Published on: November 14, 2025
08:02A High-Throughput Image-Guided Stereotactic Neuronavigation and Focused Ultrasound System for Blood-Brain Barrier Opening in Rodents
Published on: July 16, 2020