Related Experiment Video
Updated: Apr 4, 2026

Ice Generation and the Heat and Mass Transfer Phenomena of Introducing Water to a Cold Bath of Brine
Published on: March 13, 2017
A comparative analysis of multi-stage evaporative cooling and conventional chillers for office-scale cooling loads
C Chiranjeevi1, Y Raja Sekhar1, J Javith2
1School of Mechanical Engineering, Vellore Institute of Technology, Vellore, TN, 632014, India.
Abstract:
The building sector accounts for a substantial share of global electricity consumption, with HVAC systems dominating energy use in large commercial buildings, particularly in developing countries. This study presents a comparative, climate-specific performance assessment of a hybrid multi-stage evaporative cooling-chiller system, with a specific focus on modifying an indirect evaporative cooling (IEC) unit by utilizing return air as the working air stream which is a configuration rarely evaluated for Indian climatic conditions. The methodology combines psychrometric analysis, real-time system modification, and detailed building heat-load calculations for a large office-scale building across multiple Indian climate zones under summer and monsoon conditions, and benchmarks three configurations: (i) stand-alone chiller, (ii) conventional IEC-chiller system, and (iii) modified IEC-chiller system. Results show that the conventional IEC configuration reduces chiller capacity by 50-60 TR, while the modified multi-stage IEC system achieves a chiller capacity reduction of 80-140 TR, depending on climate and seasonal load. For identical cooling demands, the conventional IEC system consumes 27.53% less electrical energy than a stand-alone chiller, whereas the modified IEC-return air configuration delivers a higher reduction of 34.97%. The modified system also demonstrates superior temperature reduction and wet-bulb effectiveness, particularly under humid monsoon conditions where conventional IEC performance is typically constrained. These findings demonstrate that return-air-assisted multi-stage evaporative cooling significantly enhances chiller load reduction and energy efficiency, offering a technically viable and scalable hybrid cooling solution for large buildings in diverse Indian climates.
Related Concept Videos
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Heat Flow and Specific Heat
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Heat Capacity: Problem-Solving
Determine the type of gas: The heat capacity of a gas depends on its molecular structure and the degree of freedom of its molecules. Different types of...