Optimization of lens size and ion source parameters for gas chromatography/mass spectrometry-based metabolomics using
Momo Sato1, Ryosuke Hayasaka1, Tomoyoshi Soga2
1Institute for Advanced Biosciences, Keio University 246-2 Mizukami, Kakuganji, Tsuruoka, Yamagata 997-0052, Japan; Systems Biology Program, Graduate School of Media and Governance, Keio University, 5322 Endo, Fujisawa, Kanagawa 252-0882, Japan.
Abstract:
Gas chromatography/mass spectrometry (GC/MS) is widely employed in metabolomics owing to its high resolution, reproducibility, and compatibility with volatile and semi-volatile compounds. While helium has traditionally been used as the carrier gas, increasing costs and global shortages have prompted the exploration of hydrogen gas as an alternative. Hydrogen offers faster analysis times and reduced ion source contamination but presents challenges, including ion source reactions, which can change compound fragmentation patterns. To address this, a hydrogen-deactivated electron ionization (EI) source has been developed to minimize undesired chemical interactions and improve spectral integrity. In this study, we systematically evaluated the effect of extraction lens sizes (3, 6, and 9 mm) under hydrogen carrier gas conditions using n-alkane and human metabolomic standard solutions. The hydrogen-deactivated ion source equipped with a 3 mm extraction lens provided superior peak symmetry and the highest signal intensities, with acceptable relative standard deviation (RSD) values (i.e., below 30%). In addition, the reproducible fragmentation patterns as those observed with helium carrier gas were obtained for phosphorylated metabolites. Using this optimized configuration, we applied hydrogen gas-based GC/MS to metabolomic profiling of the human colon cancer cell line HCT116 with mutant isocitrate dehydrogenase 1 (IDH1). Key metabolic alterations, including increased levels of the known biomarker 2-hydroxyglutaric acid, were detected in IDH1-mutant cells compared with wild-type cells. These findings establish hydrogen gas-based GC/MS with a hydrogen-deactivated ion source as a robust and reliable platform for metabolomics, offering an effective alternative to helium-based systems.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Resolution Mass Spectrometry (HRMS)