Related Experiment Video
Updated: Apr 11, 2026

13:59
Reduced-gravity Environment Hardware Demonstrations of a Prototype Miniaturized Flow Cytometer and Companion Microfluidic Mixing Technology
Published on: November 13, 2014
14.3K
A situationally aware cockpit door locking system for mitigating internal threat scenarios in commercial aviation
Fuat Şaylan1, Fatih Alpaslan Kazan2
1Department of Electronics and Automation, Selçuk University, Ilgın, Konya, Türkiye.
Scientific Reports
|April 9, 2026
Abstract
No abstract available in PubMed .
Keywords:
Aviation human factorsCockpit door securityInternal threat mitigationSafety-critical embedded systemsSituational-aware access controlMore Related Videos
Related Concept Videos
Self-Locking Screw
2.7K
A square-threaded screw jack is a mechanical device widely used for lifting heavy loads or applying considerable force. One of the key features that can make a screw jack more effective and reliable is its self-locking capability.
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
2.7K
Design Example: Automobile Ignition System
619
The automobile's ignition system plays a vital role by ensuring the timely ignition of the fuel-air mixture in each cylinder. This ignition is facilitated by a spark plug, which is composed of two electrodes separated by an air gap. A spark forms across this air gap when a substantial voltage is generated between the electrodes, leading to the ignition of the fuel.
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
619
Design Example: Forces in Sluice Gate
3.7K
In hydraulic engineering, sluice gates are essential for managing water flow through channels, reservoirs, and irrigation systems. Sluice gates, acting as vertical barriers, regulate water by adjusting the gate's opening height, which changes the velocity and pressure of water flowing beneath the gate. Understanding the forces involved is crucial to designing sluice gates that can withstand dynamic pressure differences, especially when the gate is closed or partially open.
Key variables in...
Key variables in...
3.7K
Radial System Protection
483
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
483
Open and closed-loop control systems
2.0K
Control systems are foundational elements in automation and engineering. They are broadly categorized into open-loop and closed-loop systems. These classifications hinge on the presence or absence of feedback mechanisms, significantly influencing the system's performance, complexity, and application.
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
2.0K
Turbine-Governor Control
1.2K
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
1.2K

