Related Experiment Video
Updated: Apr 11, 2026

In vitro Cannabis Exposures of Lung Epithelial Cells at the Air-Liquid Interface
Published on: June 20, 2025
In vitro delivery and transwell uptake of volatile and semi-volatile organic compounds in an air-liquid interface
Ji Hyun Lee1, Hongku Lee2, Kang Ho Ahn3
1HCT Seattle, Seattle, WA, United States.
Introduction:
Volatile organic compounds (VOCs) readily penetrate the respiratory tract and cross the air-liquid interface (ALI), yet their in vitro deposition behavior and dose uniformity remain poorly characterized.
Methods:
In this study, we evaluated the delivered concentration in the basolateral compartment and inter-transwell variability of isopropyl alcohol (IPA), acetone, and benzyl alcohol (BA) in a six-transwell ALI exposure system. VOCs were generated by atomization at airflow rates of 0.2-3 L/min and delivered for 1-2 h. Delivered concentrations were quantified using photoionization detection or UV-Vis spectroscopy, and aerosol characteristics were monitored by scanning mobility particle sizing.
Results:
Despite rapid evaporation and predominantly vapor-phase transport of IPA and acetone, and semi-volatile aerosol BA, VOC delivery to the ALI was reproducible and spatially uniform. IPA and acetone exposures produced coefficients of variation (CVs) below 10% and 16%, respectively, across transwells, whereas benzyl alcohol exhibited higher variability (CV ≤ 19%) due to its lower vapor pressure and higher viscosity. No statistically significant positional differences were observed under any exposure condition.
Discussion:
These findings indicate that volatile organic compounds delivered to the ALI undergo diffusion-driven gas-liquid delivery, resulting in a relatively uniform spatial distribution. This study provides exposure-relevant delivery characterization for VOCs and semi-VOCs in ALI systems, supporting future NAM-based inhalation studies without implying biological dose equivalence.
Related Concept Videos
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Vaporization