Morphometric investigation of the infraorbital canal and determination of its "suspended" variant: a multidetector computed tomography study
Related Experiment Video
Updated: Apr 14, 2026

Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method
Published on: October 27, 2020
Mehmet Selcuk1, Hamza Kasar2, Murat Inci3
1Nigde Ömer Halisdemir University, Faculty of Medicine, Department of Anatomy, Nigde, Turkey.
Objectives:
The aim of this Multidetector Computed Tomography (MDCT) study was to investigate the morphometry and variations of the Infraorbital Canal (IOC), including the "suspended" (Type 3) variant, to highlight its clinical importance in preventing iatrogenic nerve injury during sinonasal surgeries.
Methods:
In this retrospective analysis, 600 IOCs were analyzed using MDCT images obtained from 300 patients (18-82 years old, equal gender distribution). IOCs were classified into three types according to maxillary sinus protrusion: Type 1 (no protrusion), Type 2 (partial) and Type 3 (complete/suspended). The presence of Haller cell was also evaluated.
Results:
The prevalence of type 3 IOC was 13%. Haller cells were observed in 21.2%. Type 3 IOCs exhibited significantly larger D1 (distance from the infraorbital rim to the infraorbital foramen) and D2 (maximum length of the IOC) lengths and were found in younger patients. There was a weak negative correlation between age and D1/D2. Although women were older, IOC measurements did not show a significant gender difference in Type 3 cases, except that right-sided D3 (length of the bony septum extending into the maxillary sinus) was larger than left-sided D3.
Conclusions:
Type 3 IOC is a common anatomical variation, often associated with Haller cells, that increases the risk of infraorbital nerve injury in maxillary sinus surgery. Preoperative multidetector CT imaging of these variants is crucial to improve surgical safety.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...