Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
[Determination of atmospheric intermediate volatility organic compounds with thermal desorption-flow modulator
Rui Wang1,2, Ying-Jie Li1, Jia-Hua Wang1
1Key Laboratory of Formation and Prevention of Urban Air Pollution Complex,Ministry of Ecology and Environment,Shanghai Academy of Environmental Sciences,Shanghai 200233,China.
Abstract:
Atmospheric intermediate volatile organic compounds (IVOCs) are complex mixtures. Due to the limited separation and identification capabilities of one-dimensional gas chromatography (1D-GC), a large portion of atmospheric IVOCs-which often elute as unresolved or complex peaks-are categorized as an unspeciated complex mixture (UCM). This constrains the accurate apportionment of atmospheric IVOCs. To address this problem, an alternative analytical method has been developed utilizing thermal desorption-flow modulation comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (TD-FM GC×GC-TOF MS) to measure atmospheric IVOCs. Analytical optimization focused on fill and flush time within a 3-second modulation period, with optimal values determined as 2 870 ms and 130 ms, respectively, to maximize separation efficiency and signal response. Compounds were separated on a ZB-5HT column (20 m×0.18 mm×0.18 μm) as the first dimension, with a BP-50 column (5 m×0.25 mm×0.20 μm) serving as the second dimension. Helium was employed as the carrier gas with column pressures maintained at 254.4 kPa (first dimension) and 202.1 kPa (second dimension). The following temperature program was used: 50 ℃ for 10 min, then increased to 300 ℃ at 10 ℃/min, with the final temperature held for 20 min. The MS was operated in electron impact (EI, 70 eV) ionization mode. Both the ion source and transfer line temperatures were set at 300 ℃. MS signals were recorded in full scan mode with a scan range of m/z 40 to m/z 800. During thermal desorption, the desorption temperature was set at 320 ℃, and the cold trap temperature was maintained at -10 ℃ to capture desorbed targets. The secondary desorption flow rate was set at 16 mL/min. Under these optimized conditions, the method demonstrated acceptable linearity, with correlation coefficients ranging from 0.922 3 to 0.998 4, for 69 selected targets spanning 1 to 20 ng/tube, with method detection limits (spiked at 1 ng/tube) between 0.010 7 and 0.410 1 ng/m3, with recoveries ranging from 80.4% to 136.0%. Relative standard deviation values among replicate samples (n=7) spiked at 1 ng/tube, 3 ng/tube, and 10 ng/tube levels were around 4.5%-33.9%, 3.2%-19.9% and 3.5%-18.6%, respectively. Application of the method to atmospheric IVOC samples collected from an urban site of Shanghai, revealed total IVOCs mass concentrations of 8.6-61.1 μg/m3. Of these, mass concentrations of 853 individual species identified by the present method comprised 96.2% of total IVOCs. Consequently,the newly developed method improved the identification rate for UCM. Importantly, the newly speciated aromatics, chlorinated IVOCs, and oxygenated IVOCs exhibited different emission sources distinct from those routinely monitored compounds. Therefore, this study established a reliable method for determining atmospheric IVOCs, offering strong data support for precise source apportionment of complex IVOCs in the atmosphere. Additionally, this method can be used to monitor IVOCs across various environmental metrics, thereby providing essential data to support the management and control of these compounds.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...