Related Experiment Video
Updated: Apr 14, 2026

Ultrasound Imaging-guided Intracardiac Injection to Develop a Mouse Model of Breast Cancer Brain Metastases Followed by Longitudinal MRI
Published on: March 6, 2014
Integrated ultrasound-based radiomics and deep learning models in screening breast intraductal high-risk lesions or
Na Li1, RuiJiao Chang2, Bo Jiang3
1Department of Ultrasound, The 4th (Xing Yuan) Hospital of Yulin, Yulin, Shaanxi, China.
Purpose:
The aim of this study was to explore the diagnostic performance of ultrasound (US)-based radiomics combined with deep learning (DL) in the screening of high-risk and malignant intraductal breast lesions.
Methods:
This multicenter retrospective study included patients with breast intraductal lesions from January 2022 to June 2024 from five hospitals in China. In the training set, conventional US images were segmented and radiomics features were extracted. After feature selection using least absolute shrinkage and selection operator (LASSO) regression, a radiomics model was developed using logistic regression, and the DL model was constructed based on ResNet-50. An integrated model was constructed by fusing the predicted probabilities from single models. The diagnostic performance of US, radiomics, DL, and integrated models was compared in the internal and external validation sets.
Results:
A total of 785 lesions were collected, including 486 benign lesions and 299 high-risk or malignant lesions. In the training set (520 lesions), the integrated model achieved superior performance (area under the curve (AUC) = 0.946 [0.923, 0.964]) to that of the US model (AUC = 0.774 [0.732, 0.816]; p < 0.001) and the DL model (AUC = 0.873 [0.841, 0.905]; p < 0.001). In the internal validation (130 lesions) and external validation sets (135 lesions), the integrated model achieved the best AUC (internal: 0.891 [0.825, 0.939], external: 0.861 [0.791, 0.914]) among all single models (p < 0.05). Among single models, in the training set, the radiomics model (AUC = 0.938 [0.919, 0.958]) outperformed both US (AUC = 0.774 [0.732, 0.816], p < 0.0001) and DL models (AUC = 0.873 [0.841, 0.905], p < 0.001). In the external validation set, the AUC of the radiomics model (AUC = 0.827 [0.760, 0.895]) was higher than that of the US model (AUC = 0.651 [0.564, 0.731], p = 0.011).
Conclusion:
The integrated radiomics and DL model demonstrated potential clinical value in screening the high-risk or malignant breast intraductal lesions.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
13:43Intraductal Delivery and X-ray Visualization of Ethanol-Based Ablative Solution for Prevention and Local Treatment of Breast Cancer in Mouse Models
Published on: April 1, 2022