Background:
Nuchal translucency (NT) is an important ultrasound indicator in early pregnancy. Increased NT is strongly associated with chromosomal abnormalities, structural defects, and other adverse outcomes. However, the low signal-to-noise ratio (SNR), numerous artifacts, and poor contrast present in ultrasound images pose considerable challenges to existing segmentation methods.
Purpose:
To address these challenges, this paper proposes a novel Transformer model, TransNTSeg, for NT segmentation. This study serves as a preliminary proof-of-concept to evaluate the feasibility of the proposed architecture.
Methods:
A clinical dataset of 123 B-mode ultrasound images is collected. To ensure rigorous evaluation, the dataset is partitioned into 98 images for training/validation (using 5-fold cross-validation) and 25 images for independent testing. The architecture incorporates two main innovations: first, an enhanced Dense Dilated Mixed Feed-Forward Network (DDMix-FFN) module within the Transformer that more robustly integrates global dependencies and local context to handle image noise and boundary ambiguity; and second, a DDMix-FFN Transformer context bridge that fuses multi-scale encoder features for precise localization of the small NT region. Performance is compared against eight state-of-the-art benchmarks (e.g., U-Net, MT-UNet) using Intersection over Union (IoU) and Dice Similarity Coefficient (DSC). Statistical significance is assessed using the paired t-test with Bonferroni correction to control for multiple comparisons (adjusted p < 0.0015625), and practical significance is quantified using Cohen's dz effect size.
Results:
TransNTSeg achieves the highest performance on the test dataset, with a mean IoU of 0.763 ± 0.05 and a mean DSC of 0.852 ± 0.03. Rigorous statistical analysis (Bonferroni corrected p < 0.0015625) confirms considerable improvements. Based on the evaluation of effect sizes, TransNTSeg is identified as the best-performing method, demonstrating a substantial effect size (d = 0.745) against the closest competitor (MT-UNet).
Conclusion:
While demonstrating competitive performance within this controlled setting, these promising outcomes highlight the potential of TransNTSeg for accurate NT segmentation. This warrants further validation on multicenter, multi-vendor datasets to establish its generalizability for broad clinical use.