Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Apr 14, 2026

An Experimental Human DIEP Flap Model to Investigate Preservation Strategies for Vascularized Composite Allografts and Free Flaps
07:57

An Experimental Human DIEP Flap Model to Investigate Preservation Strategies for Vascularized Composite Allografts and Free Flaps

Published on: December 5, 2025

435

Robotic Peritoneal Flap Revision Vaginoplasty: Step-by-Step Technique: Tips & Tricks.

V Celis1, V I Rodríguez1, L K Fumero1

  • 1The Catherine and Joseph Aresty Department of Urology, USC Institute of Urology, Keck School of Medicine, University of Southern California, 1441 Eastlake Ave., Suite 7416 90089-9178, Los Angeles, CA, USA.

International Urogynecology Journal
|April 13, 2026
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Safety and early organ preservation outcomes after dose escalation with MR-guided radiotherapy for rectal cancer (preRADAR): A phase I trial.

Clinical and translational radiation oncology·2026
Same author

Predicting locoregional treatment failure in anal cancer using multivariable clinical-imaging models.

Clinical and translational radiation oncology·2026
Same author

Nationwide implementation of Watch-and-Wait in rectal cancer patients in the Netherlands: Encountered barriers and lessons learned in 20 years.

Health policy (Amsterdam, Netherlands)·2026
Same author

Surgical Determinants of Outcomes in Partial Nephrectomy: a Contemporary Review.

Current urology reports·2026
Same author

Lower limb clinical osteoarthritis and its association with joint pain and function, and severe injuries and surgeries, in women professional football players: a cross-sectional observational study.

South African journal of sports medicine·2025
Same author

Impact of sociodemographic and socioeconomic factors on functional and health-related quality of life outcomes 24 months after radical prostatectomy.

Journal of cancer research and clinical oncology·2025
This summary is machine-generated.

Robotic peritoneal flap vaginoplasty revision is a safe and feasible surgical option for transgender women experiencing vaginal canal stenosis after initial vaginoplasty. This technique effectively restores vaginal patency and depth.

Area of Science:

  • Surgical innovation in gender-affirming care
  • Minimally invasive reconstructive surgery
  • Transgender women's health

Background:

  • Penile inversion vaginoplasty is common for transgender women but has high revision rates.
  • Vaginal canal stenosis or shortening is a frequent functional complication requiring revision surgery.
  • Revision vaginoplasty presents unique surgical challenges, particularly in flap reconstruction.

Purpose of the Study:

  • To present a step-by-step technique for robotic peritoneal flap revision vaginoplasty.
  • To discuss the indications, challenges, and postoperative management of this revision procedure.
  • To evaluate the feasibility and outcomes of robotic revision vaginoplasty.

Main Methods:

  • Detailed description of the robotic peritoneal flap vaginoplasty revision technique.
Keywords:
Feminizing genital reconstructionPeritoneal flapRobotic surgerySurgical techniqueTransgenderVaginoplasty

More Related Videos

Laparoscopic Oocyte Retrieval and Cryopreservation during Vaginoplasty for Treatment of Mayer-Rokitansky-Kuster-Hauser Syndrome
11:53

Laparoscopic Oocyte Retrieval and Cryopreservation during Vaginoplasty for Treatment of Mayer-Rokitansky-Kuster-Hauser Syndrome

Published on: May 10, 2022

4.5K
Engineered Vascularized Muscle Flap
08:18

Engineered Vascularized Muscle Flap

Published on: January 11, 2016

8.8K

Related Experiment Videos

Last Updated: Apr 14, 2026

An Experimental Human DIEP Flap Model to Investigate Preservation Strategies for Vascularized Composite Allografts and Free Flaps
07:57

An Experimental Human DIEP Flap Model to Investigate Preservation Strategies for Vascularized Composite Allografts and Free Flaps

Published on: December 5, 2025

435
Laparoscopic Oocyte Retrieval and Cryopreservation during Vaginoplasty for Treatment of Mayer-Rokitansky-Kuster-Hauser Syndrome
11:53

Laparoscopic Oocyte Retrieval and Cryopreservation during Vaginoplasty for Treatment of Mayer-Rokitansky-Kuster-Hauser Syndrome

Published on: May 10, 2022

4.5K
Engineered Vascularized Muscle Flap
08:18

Engineered Vascularized Muscle Flap

Published on: January 11, 2016

8.8K
  • Inclusion of surgical tips and step-by-step guidance.
  • Outline of postoperative care, including vaginal packing, catheter management, and discharge planning.
  • Main Results:

    • Robotic peritoneal flap vaginoplasty revision is feasible and safe.
    • Average operative time was 3 hours with an estimated blood loss of 20 ml.
    • Postoperative management included early discharge, with serial vaginoscopies to ensure patency.

    Conclusions:

    • Harvesting a peritoneal flap is feasible even after prior perineal flap surgery.
    • Robotic revision vaginoplasty effectively re-establishes vaginal canal patency and depth.
    • This procedure offers a viable solution for transgender women needing vaginal reconstruction revision.