Carbon disulfide - Determination of carbon disulfide in workplace air using headspace gas chromatography
Andreas Grill1, Claus-Peter Maschmeier2, Ralph Hebisch3
1Kelheim Fibres GmbH Regensburger Str. 109 93309 Kelheim Germany.
Abstract:
The working group "Air Analyses" of the German Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK Commission) developed and verified the presented analytical method. It is used to determine the levels of carbon disulfide [75-15-0] that occur in the workplace air. The method covers concentrations in the range from one tenth to twice the current German occupational exposure limit value (OELV) of 30 mg/m3. It is also suitable for monitoring compliance with the MAK value of 16 mg/m3 and the short-term exposure limit (STEL; excursion factor 2). Samples are collected by drawing a defined volume of air through a sampling tube filled with activated charcoal using a flow regulated pump at a maximal volumetric flow rate of 0.333 l/min. Exposure during the shift is measured with a sampling period of 2 hours (up to 8 hours, depending on the volumetric flow) and the short-term exposure with a period of 15 minutes. The carbon disulfide adsorbed to the activated charcoal is extracted with toluene and analysed by headspace gas chromatography with flame photometric detection. The quantitative determination is based on multiple-point calibrations with an internal standard. A relative limit of quantification (LOQ) of 0.5 mg/m3 is obtained for an air sample volume of 40 litres and an application volume of 18 ml. As the relative LOQ for a sample volume of 5 litres is below 5 mg/m3, the STEL can also be measured. The recovery, which has to be considered for the calculation of the results, is approx. 70% and the expanded uncertainty is below 22% for a sampling period of 2 hours and below 23% for a period of 15 minutes.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
05:00Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
Published on: July 26, 2024
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...