Related Experiment Video
Updated: Apr 15, 2026

Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
Generating Findings for Jaw Cysts in Dental Panoramic Radiographs Using a GPT-Based VLM: A Preliminary Study on
Nanaka Hosokawa1, Ryo Takahashi2, Tomoya Kitano3
1Graduate School of Natural Science and Technology, Gifu University, Gifu 501-1193, Japan.
Abstract:
Background/Objectives: Vision-language models (VLMs) such as GPT (Generative Pre-Trained Transformer) have shown potential for medical image interpretation; however, challenges remain in generating reliable radiological findings in clinical practice, as exemplified by dental pathologies. This study proposes a Self-correction Loop with Structured Output (SLSO) framework as an integrated processing methodology to enhance the accuracy and reliability of AI-generated findings for jaw cysts in dental panoramic radiographs. Methods: Dental panoramic radiographs with jaw cysts were used to implement a 10-step integrated processing framework incorporating image analysis, structured data generation, tooth number extraction, consistency checking, and iterative regeneration. The framework functioned as an external validation mechanism for GPT outputs. Performance was compared against the conventional Chain-of-Thought (CoT) method across seven evaluation items: transparency, internal structure, borders, root resorption, tooth displacement, relationships with other structures, and tooth number. Results: The SLSO framework improved output accuracy for multiple items compared to the CoT method, with the most notable improvements observed in tooth number identification, tooth displacement detection, and root resorption assessment. In successful cases, consistently structured outputs were achieved after up to five regenerations. The framework enforced explicit negative finding descriptions and suppressed hallucinations, although accurate identification of extensive lesions spanning multiple teeth remained limited. Conclusions: This investigation established the feasibility of the proposed integrated processing methodology and provided a foundation for future validation studies with larger, more diverse datasets.
Related Concept Videos
Imaging Studies VI: Voiding Cystourethrography and Cystography
Urologic Endoscopic Procedure: Cystoscopic Examination
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...