Modern Fluorescence Strategies for Honey Characterization: Analytical Advances, Emerging Technologies, Methodological

Krastena Nikolova1, Daniela Batovska2, Galia Gentscheva3

  • 1Department of Physics and Biophysics, Faculty of Pharmacy, Medical University of Varna, 84 Tzar Osvoboditel Blvd., 9000 Varna, Bulgaria.

Summary

Fluorescence spectroscopy offers a rapid, cost-effective method for screening honey authenticity. This technique analyzes intrinsic fluorescence to detect adulteration, complementing traditional methods.

Related Concept Videos

Methods to Assess Microbial Populations01:30

Methods to Assess Microbial Populations

Assessing microbial populations is crucial for understanding microbial roles in health, ecology, and industry. Various complementary techniques—both culture-based and molecular—enable detailed analysis of microbial abundance, diversity, and function.Viable Plate CountThe viable plate count is a traditional culture-based method used to estimate the number of living microbes in a sample. After serial dilution, the sample is spread onto nutrient agar plates. Each viable cell forms a...
76
Immunofluorescence Microscopy01:12

Immunofluorescence Microscopy

A fluorescence microscope uses fluorescent chromophores called fluorochromes, which can absorb energy from a light source and then emit this energy as visible light. Fluorochromes include naturally fluorescent substances (such as chlorophylls) and fluorescent stains that are added to the specimen to create contrast. Dyes such as Texas red and FITC are examples of fluorochromes. Other examples include the nucleic acid dyes 4’,6’-diamidino-2-phenylindole (DAPI), and acridine orange.
14.9K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.9K
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
2.0K
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K