Related Experiment Video
Updated: Apr 15, 2026

Ultrasonic Welding of Thermoplastic Composite Coupons for Mechanical Characterization of Welded Joints through Single Lap Shear Testing
Published on: February 11, 2016
Ultrasonic Testing of Laser Welds in Medium-Thick Titanium Alloy Plates
Chenju Zhou1, Jie Li1, Shunmin Yang1
1State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China.
None:
To address the challenge of detecting internal defects in medium-thick titanium alloy laser welds, a combined simulation and experimental study on ultrasonic testing was conducted. A finite element model employing a 5 MHz shear wave angle transducer for inspecting titanium alloy welds was established. An ultrasonic testing system was developed, incorporating a DPR300 pulser-receiver (JSR Ultrasonics, Pittsford, NY, USA) and an MSO5204 oscilloscope (RIGOL, Suzhou, China), and was calibrated using standard reference blocks. The inspection results for four prefabricated internal defects at various depths demonstrated that all defects were effectively detected, with the minimum detectable equivalent defect size reaching 1 mm. The measured signal-to-noise ratio (SNR) averaged 17.6 dB, validating the high sensitivity of the proposed system. The mean absolute error for defect localization was 0.438 mm, achieving a positioning accuracy better than 0.5 mm. This study indicates that the pro-posed method enables effective detection and accurate localization of internal defects in titanium alloy laser welds, providing critical technical support for laser welding quality assessment.