Related Experiment Video
Updated: Apr 15, 2026

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Experimental Laboratory Study on the Acoustic Response Characteristics of Fluid Flow in Horizontal Wells Based on
Geyitian Feng1, Zhengting Yan1, Jixin Li2
1National Key Laboratory of Petroleum Resources and Engineering, China University of Petroleum-Beijing, Beijing 102249, China.
None:
Distributed acoustic sensing (DAS) has been widely applied to injection-production profile monitoring in horizontal wells because it provides continuous full-wellbore coverage, real-time acquisition, and straightforward long-term deployment. In practical downhole operations, however, DAS measurements are frequently compromised by optical-signal attenuation, loss of fiber-casing/formation coupling, and environmental noise. Meanwhile, the mechanisms governing flow-induced acoustic responses remain insufficiently understood, which continues to impede quantitative diagnosis and interpretation of injection-production profiles based on DAS data. To address these challenges, this study performed controlled laboratory-scale physical simulation experiments of single-phase flow in a horizontal wellbore, systematically investigating DAS acoustic responses under two wellbore diameters (25 mm and 50 mm) and a range of flow velocities. Power spectral density (PSD) was derived using the fast Fourier transform to identify flow-sensitive characteristic frequency bands, and frequency-band energy (FBE) was further used to establish an optimal quantitative relationship with flow velocity. The results show that: (1) DAS energy is dominated by low-frequency components (<100 Hz), with the total energy increasing nonlinearly as flow velocity rises, accompanied by a progressive broadening of the characteristic bands; (2) the feature bands identified using an adaptive method based on energy difference statistics applied to PSD frequency-domain features exhibit a higher signal-to-noise ratio and greater physical clarity than traditional wide frequency bands; furthermore, by employing a feature band merging strategy, the distribution characteristics of flow energy can be captured more comprehensively; and (3) FBE exhibits a strong nonlinear dependence on flow velocity, with a power-law model delivering the best theoretical fit, whereas a cubic model (FBE ∝ V3) achieves high accuracy and robustness for practical applications. The proposed workflow-"PSD peak identification-characteristic band delineation-FBE regression"-establishes a methodological foundation for quantitative DAS-based monitoring of horizontal-well injection-production profiles in both laboratory and field settings, and it provides a basis for subsequent intelligent monitoring and interpretation under multiphase-flow conditions.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...