Tests of HgCdTe Photodetectors Performances for Implementation on the MIST-A Instrument
Chiara Cencia1,2, Eliana La Francesca1, Mauro Ciarniello1
1Institute for Space Astrophysics and Planetology (IAPS), National Institute of Astrophysics, 00133 Rome, Italy.
None:
The Middle-Wave Infrared Imaging Spectrometer for Target Asteroids (MIST-A) will be launched in 2028 aboard the Emirates Mission to the Asteroid belt (EMA) and will operate in the 2-5 μm spectral range to study the asteroids' surface composition and thermo-physical properties. MIST-A's Optical Head (OH) design is inherited from the Jovian IR Auroral Mapper (JIRAM), from which the instrument also received two spare Hybrid-Thinned Mercury-Cadmium-Telluride (MCT) photodetectors: the Engineering Model EM2 and the Flight Spare FS1. These are tested to assess their performance after a long period of storage. The laboratory setup for testing both detectors consists of a blackbody and a cryostat which houses the focal plane, maintained at temperatures of 85 K, its nominal operative temperature, and 90 K. Two sets of measurements are performed: (1) characterization of the dark current at different integration times (0 ms, 224 ms, 448 ms, 672 ms, 869 ms, 1120 ms); (2) verification of the detectors' response linearity, measuring a blackbody at different temperatures (from 50 °C to 100 °C), including ambient temperature (25 °C, with the blackbody turned off). The results of these tests confirm that both models are fully operational and allow us to evaluate the consequences of the years of inactivity on their performance. Through a detailed analysis of the detectors' properties and a comparison study with the results of the sensors' first characterization performed by their producer in 2009, we come to the conclusion that both instruments are able to fulfill MIST-A's scientific requirements. The FS1 displays a better performance with respect to the EM2 and for this has been selected as MIST-A's Flight Model.
More Related Videos
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass ADG Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...