Abstract:
Cancer is a leading global cause of morbidity and mortality, with inter- and intra-tumor heterogeneity contributing to suboptimal therapeutic outcomes. While genomic profiling has advanced precision oncology, many tumors lack targetable mutations, underscoring the need for functional assays. Here, we present a drug sensitivity testing platform for patient-derived organoids (PDOs) based on active-matrix digital microfluidics (AM-DMF). The system comprises a microfluidic timing-control board (<50 ms switching precision), a temperature-regulation module (37 ± 0.3 °C) and an integrated imaging module for multiscale visualization. Droplet generation, transport, mixing, and dilution on the AM-DMF platform are programmably controlled via electrowetting-on-dielectric (EWOD) actuation, with volume stability from 1 to 100 nL per droplet (CV < 3%). A multilayer design of the AM-DMF chips suppressed crosstalk and leakage current, enabling stable operation over 10 h. PDO-loaded droplets were efficiently generated through symmetric "one-to-two" splitting, achieving >71% success within 4-5 tearing cycles. Evaluation of cisplatin cytotoxicity across multiple PDOs on AM-DMF chips revealed time- and dose-dependent responses, including early morphological contraction (12 h) and subsequent structural disintegration (72 h) at high concentrations. Live/dead staining confirmed membrane damage under high-dose treatment, reflected by increased red fluorescence. Quantitative analysis demonstrated consistent dose-dependent inhibition of viability across all PDOs. Notably, on-chip measurements showed response trends consistent with conventional 96-well plate assays, yet with moderately higher inhibition rates, indicating enhanced assay sensitivity. Overall, we have developed an automated, high-throughput drug-testing system for PDOs, wherein the entire workflow, including organoid culture, precise drug concentration gradient generation, multi-dose drug screening, staining, and imaging, was seamlessly integrated and performed on a single active-matrix digital microfluidics chip. Collectively, this integrated AM-DMF platform offers a systematic, scalable strategy for functional precision medicine, especially suited to scarce clinical specimens and complex multidrug regimens.
Insights
We developed a novel drug sensitivity testing platform using active-matrix digital microfluidics (AM-DMF) for patient-derived organoids (PDOs). This high-throughput system enables precise drug screening for personalized cancer therapy.
Area of Science:
- Biotechnology and Biomedical Engineering
- Cancer Research and Precision Oncology
Background:
- Cancer heterogeneity poses challenges to effective treatment, driving the need for functional drug sensitivity assays beyond genomic profiling.
- Patient-derived organoids (PDOs) offer a promising model for personalized cancer therapy but require efficient drug screening platforms.
Purpose of the Study:
- To develop and validate an automated, high-throughput drug sensitivity testing platform for PDOs utilizing active-matrix digital microfluidics (AM-DMF).
- To integrate organoid culture, drug gradient generation, screening, staining, and imaging onto a single microfluidic chip for functional precision medicine.
Main Methods:
- Development of an AM-DMF system with precise timing control, temperature regulation, and integrated imaging.
- Programmable droplet generation, transport, mixing, and dilution using electrowetting-on-dielectric (EWOD) actuation for PDO handling.
- Evaluation of cisplatin cytotoxicity on PDOs using the AM-DMF platform, including morphological and viability assessments.
Main Results:
- The AM-DMF platform demonstrated stable operation with precise droplet volume control (1-100 nL, CV < 3%) and efficient PDO droplet generation (>71% success).
- On-chip drug screening revealed time- and dose-dependent cytotoxic effects of cisplatin on PDOs, consistent with conventional assays but with potentially higher sensitivity.
- Integrated workflow from organoid culture to multi-dose drug screening and imaging was successfully demonstrated on a single chip.
Conclusions:
- The integrated AM-DMF platform provides a systematic and scalable solution for high-throughput drug sensitivity testing of PDOs.
- This technology facilitates functional precision medicine, particularly for scarce clinical specimens and complex drug regimens, improving therapeutic outcomes.