Related Experiment Video
Updated: Apr 17, 2026

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Temperature-triggered nitinol manipulation for explantation of self-expanding transcatheter aortic valves: a case
Lauren A Gillinov1, Michael P Salna2, Brittany J Cannon2
1Division of Cardiovascular Surgery, Department of Surgery, University of Pennsylvania, 1 Convention Ave, Philadelphia, 19104, PA, USA. lauren.gillinov@pennmedicine.upenn.edu.
Background:
Transcatheter aortic valve explantation is the fastest-growing cardiac operation in the United States, yet optimal techniques are not well-defined.
Case Presentation:
Here, we present a case of explantation of a self-expanding CoreValve Evolut PRO valve (Medtronic, Minneapolis, Minnesota).
Conclusions:
This report demonstrates a reproducible technique that leverages the temperature-dependent properties of nitinol to facilitate safe surgical explantation of self-expanding transcatheter aortic valves.