Related Experiment Video
Updated: Apr 18, 2026

Fabrication of Soft Pneumatic Network Actuators with Oblique Chambers
Published on: August 17, 2018
Design and evolution of a triad twisted string actuator for controlling a two degrees of freedom joint: improving
Damian Crosby1, Joaquin Carrasco2, William Heath3
1Department of Mechanical and Aerospace Engineering, School of Engineering, Faculty of Science and Engineering, The University of Manchester, Manchester, United Kingdom.
Abstract:
Actuated universal joints are used in a wide range of robotic applications, including mobile snake robots, snake-arm robots and robotic tails. They are employed in applications such as search and rescue and confined space inspection. These can use remote cables, fluid driven systems, or inline motors. To realise the benefits of inline actuation while keeping the system compact with a high power to weight ratio, an actuated universal joint (AUJ) was developed using an ''antagonistic triad'' of three twisted string actuators in our previous work. However, the design had numerous drawbacks in its prototype form, namely, a limited angle range, poor accuracy due to the angular feedback sensors used, and issues with string failure due to mechanical design choices. In this publication, we performed a root-cause analysis of these issues, and partially or fully mitigated some of them by reducing the distance between the twisted string actuator (TSA), removing geometry which caused premature string failure, and exchanging the angular feedback sensors for more accurate ones. As a result, angle range was increased from 14.5° to 26° for a single axis, and 6° to 20° for a dual axis movement. Angular feedback sensor accuracy increased from 0.21° to 0.11°, and no string failures occurred within load limits. The performance of the mechanism was further characterised with additional experiments for increased follower load and angular velocity. A novel method to adjust the transmission ratio during operation (active transmission adjustment) was proposed and simulated, and its advantages over existing mechanisms for a snake robot in a multi-segment configuration were theoretically evaluated.
Related Concept Videos
Three-Dimensional Force System
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Three-Dimensional Force System:Problem Solving
To solve a three-dimensional force system, first resolve each force into its respective scalar components. Do this using...
Development of the Limb Synovial Joints
The mesenchymal stem cells differentiate into chondrocytes that form the hyaline cartilage, and later the cartilaginous model of the bone. This model further transforms into a bone. This process is known as endochondral ossification.
During development, the limbs...
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...
Bending and Torsional Moments
The reaction developed in a structural element when subjected to an external force causes the element to bend. When a structural element bends upwards, it creates compressive normal forces on the top and tensile normal forces on the bottom, resulting in a couple that determines the bending...

