Development of a Midinfrared Cavity Ring-Down Spectrometer for High-Precision Analysis of Carbon Dioxide Clumped
Ningwu Liu1, Kota Tsuge1, Ryohei Terabayashi1
1Department of Applied Energy, Nagoya University, Nagoya 464-8602, Japan.
Abstract:
A midinfrared cavity ring-down (CRD) spectrometer was developed employing a 4.44 μm quantum cascade laser (QCL) for the sensitive detection of CO2 isotopologues, including 12C16O2 (44), 13C16O2 (45), 12C16O18O (46), and 13C16O18O (47). Instead of using an acousto-optic modulator (AOM), rapid QCL current switching was employed to initiate ring-down events, effectively reducing optical losses typically introduced by the AOM and simplifying the system design. The spectrometer incorporated a high-finesse (∼50,000) optical cavity, achieving a minimum detectable absorption coefficient (MDAC) of 2.2 × 10-11 cm-1 with 14.5 s average time. A continuous frequency sweep within a 0.2 cm-1 spectral window enabled simultaneous analysis of the four target isotopologues. Allan deviation analysis over a 6 h continuous measurement revealed optimal detection precisions of 0.45 ‰ for δ45/44, 0.28 ‰ for δ47/46, 0.47 ‰ for δ46/44, 0.35 ‰ for δ47/45, and 0.3 ‰ for δ47/44 at 65 min averaging time, demonstrating excellent long-term stability and high detection precisions. Coupled with a dedicated gas handling system, the instrument enabled analysis of gas volumes as small as ∼10 mL. The CRDS system further demonstrated robust performance in real-sample analyses, exhibiting strong linear agreement with isotope ratio mass spectrometry (IRMS). High-precision determinations of the δ13C, δ18O, and δ 47/44 isotope ratios were successfully achieved.
More Related Videos
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
IR Spectrometers
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Emission Spectroscopy: Instrumentation