Detection of progression of asymptomatic severe aortic stenosis using Apple Watch-estimated maximal oxygen

Mukhtar Al-Saadi1, Aswin Srinivasan1, Elizabeth Langlois2

  • 1Department of Cardiology, HCA Houston/University of Houston College of Medicine, 1200 Binz St., Houston, TX 77004, USA.

Abstract

Related Concept Videos

Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
3.1K
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
2.1K
Mitral Stenosis II: Clinical features and Diagnostic Tests01:23

Mitral Stenosis II: Clinical features and Diagnostic Tests

Mitral stenosis is a heart condition in which the mitral valve, which allows blood to flow from the left atrium to the left ventricle, becomes narrowed or stenotic. This narrowing hinders blood flow and leads to clinical symptoms requiring specific medical evaluations and management strategies. The following overview outlines the clinical symptoms, assessments, diagnostic findings, prevention methods, and treatments for mitral stenosis.Clinical ManifestationsDyspnea (shortness of breath): This...
520
Aortic Regurgitation II: Clinical Features and Diagnostic Tests01:22

Aortic Regurgitation II: Clinical Features and Diagnostic Tests

Aortic valve regurgitation (AR) occurs when the aortic valve fails to close properly, allowing blood to flow backward from the aorta into the left ventricle. This backflow can result in two distinct clinical presentations: acute and chronic AR, each characterized by its own set of symptoms and physical findings.Acute Aortic RegurgitationAcute AR presents with a sudden onset of severe symptoms. Patients typically experience profound dyspnea (shortness of breath), chest pain, and signs of left...
1.0K
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
1.6K
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
1.5K