Related Experiment Video
Updated: Apr 21, 2026

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Detection of progression of asymptomatic severe aortic stenosis using Apple Watch-estimated maximal oxygen
Mukhtar Al-Saadi1, Aswin Srinivasan1, Elizabeth Langlois2
1Department of Cardiology, HCA Houston/University of Houston College of Medicine, 1200 Binz St., Houston, TX 77004, USA.
Background:
Symptomatic aortic stenosis (AS) constitutes a class I indication for aortic valve intervention, either by surgical or transcatheter aortic valve replacement (TAVR). Progressive AS can reduce maximal oxygen consumption (MVO2), yet this parameter is not routinely evaluated in clinical practice.
Case Summary:
We present a case of a 68-year-old with hypertension and hyperlipidaemia, initially diagnosed with moderate AS [aortic valve area (AVA) 1.3 cm2, mean gradient 23 mmHg, peak velocity 3.2 m/s]. He was asymptomatic and maintained a high level of physical activity, including treadmill running. Over the course of 3 years, the patient used an Apple Watch® to monitor estimated VO2 max. Despite stable exercise tolerance, his recorded VO2 max decreased progressively from 36 to 26 mL/kg/min. Concerned by the trend, he sought our evaluation. Repeat echocardiography showed severe AS (AVA 0.6 cm2, mean gradient 43 mmHg, peak velocity 4.29 m/s) with preserved left ventricular ejection fraction (LVEF 60%-65%). The patient subsequently underwent TAVR with a 26 mm Edwards Lifesciences Sapien 3 Ultra Valve®. At 1-year follow-up, his Apple Watch-derived VO2 max improved to 41 mL/kg/min. Echocardiography confirmed a well-seated prosthesis with a mean gradient of 9 mmHg.
Discussion:
This case illustrates the potential utility of consumer wearable technology (Apple Watch) for detecting progressive asymptomatic AS using estimated VO2 max feature. Continuous tracking of estimated VO2 max may serve as an adjunct parameter to guide timing of intervention in selected patients.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Mitral Stenosis II: Clinical features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: