Spatial temperature monitoring of preterm infants using a multi-modal camera setup
Related Experiment Video
Updated: Apr 22, 2026

Transcutaneous Microcirculatory Imaging in Preterm Neonates
Published on: December 31, 2015
Florian Voss1, Simon Lyra2, Celine Noehl2
1Medical Information Technology, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, 52074, Aachen, Germany. voss@hia.rwth-aachen.de.
Abstract:
Accurate and reliable skin temperature monitoring is critical for the thermoregulation of premature infants, but current methods using wired sensors are invasive and prone to error. Infrared thermography offers a non-invasive, wireless alternative to current wired temperature monitoring methods. This work presents a novel non-contact system for monitoring skin temperature of premature infants in closed incubators using infrared thermography. To enable temperature monitoring of specific body parts, an automated body part segmentation model was developed. The multimodal U-Net incorporated color and long-wave infrared image data. Transfer learning and data augmentation techniques improved the performance of the model, resulting in an average Intersection over Union of 0.77 across all body parts (head, torso, arms, and legs). To ensure the accuracy of the thermal data itself, a novel temperature correction algorithm was developed. This compensated for systematic errors caused by factors such as an infrared window, reflections from incubator walls, and camera drift. The algorithm achieved a mean absolute error of 0.17 [Formula: see text]C and a maximum error of 0.83 [Formula: see text]C when validated against a blackbody reference. By combining these steps, our system extracts spatial temperature using a percentile-based method, resulting in a mean absolute error of 0.41 [Formula: see text]C compared to a reference adhesive temperature sensor on the torso. The analysis revealed that the torso and arms provided more robust central and peripheral temperature measurements than the head and legs. These results demonstrate the potential of this non-contact system for accurate and reliable clinical temperature monitoring in premature infants, offering significant benefits in terms of patient comfort, reduced risk of infection and improved workflow for medical staff.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...