Related Experiment Video
Updated: Apr 22, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Technology Assistance Mitigates the Volume-Dependent Risk of Hip Dislocation Following Total Hip Arthroplasty
Avinash Iyer1, Sahil S Telang, McKenzie C Culler
1Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, California.
Background:
Lower surgeon case-volume has been associated with a greater risk of postoperative complications such as dislocation following total hip arthroplasty (THA). However, robotic assistance and computer navigation may mitigate the volume-dependent risk of instability. This study sought to compare dislocation rates between lower-volume surgeons performing technology-assisted (TA) THAs and higher-volume surgeons utilizing conventional instrumentation (CI).
Methods:
The Premier Healthcare Database was queried to identify adult patients who underwent primary elective THA from 2016 to 2023. Surgeons with <10% technology use formed the CI group, and surgeons with ≥90% technology use formed the TA group. These groups were further subdivided into higher-volume (HV) and lower-volume (LV) on the basis of surgeon annual case-volume, using a previously validated threshold of 109 cases/year. Mixed-effects modeling was used to compare the 90-day risk of dislocation between patients treated by low-volume surgeons using TA (LV-TA group) and high-volume surgeons using CI (HV-CI group).
Results:
A total of 669,098 patients undergoing THA were identified. Of these, 5,447 patients were treated by LV-TA surgeons and 190,550, by HV-CI surgeons. Notably, LV-TA surgeons achieved a similar rate of dislocation compared with HV-CI surgeons (0.48% versus 0.42%, p = 0.510). After controlling for confounding factors, the risk of dislocation remained comparable between LV-TA and HV-CI surgeons (adjusted odds ratio: 1.062, 95% confidence interval: 0.677 to 1.668, p = 0.793).
Conclusions:
Surgeons with a lower case-volume who used technology assistance achieved a rate of dislocation similar to that of surgeons with a higher case-volume who used conventional instrumentation. These findings demonstrate that technology assistance, including computer navigation and robotic assistance, may attenuate the association between surgeon case-volume and dislocation risk following primary THA.
Level Of Evidence:
Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
08:40Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
Published on: April 19, 2024