Related Experiment Video
Updated: Apr 22, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
The Potency of DCLGAN for Reducing Scan time in PET/CT imaging with different radiotracers of clinical importance
Dongwoo Kim1, Ga Yeon Kim1, Seungbeom Seo1
1From the Department of Nuclear Medicine (D.K.), Hallym University Sacred Heart Hospital, College of Medicine, Hallym University, Seoul, Republic of Korea; Yonsei University College of Medicine (G.Y.K., S.S., Y.Y.), Department of Computer Science (K.C.), Nuclear Medicine (D.K., S.L., H.L., S.K.), Artificial Intelligence (H.H., D.K.), Yonsei University, Seoul, Republic of Korea.
Background And Purpose:
Shortening PET/CT acquisition without degrading diagnostic or quantitative performance would improve patient comfort and scanner throughput. We evaluated a Dual-Contrastive Learning GAN (DCLGAN) for reconstructing high-quality neuro-PET images from reduced-time acquisitions across three clinically used tracers (18F-florbetaben (FBB), 18F-FDG, and 18F-FP-CIT) benchmarking against representative state-of-the-art deep learning models.
Materials And Methods:
In this single-center retrospective study of symptomatic patients undergoing neuro-PET/CT, list-mode data from full-time acquisitions (20 min for FBB; 15 min for FDG and FP-CIT) were reconstructed into 3- and 5-minute images. DCLGAN was trained to translate short-time to full-time appearance; raw images and standard 2.5D U-Net served as comparators. Image quality was quantified by normalized root-mean-square error (NRMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM). Two blinded nuclear medicine physicians graded clinical image quality on a five-point scale; inter-reader agreement used Cohen's kappa. Quantitative agreement of standardized uptake value ratio (SUVR) for FBB/FDG and specific binding ratio (SBR) for FP-CIT between predicted and full-time images was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis.
Results:
With DCLGAN at 5 minutes, image-quality metrics approached full-time performance across tracers: for FBB, NRMSE 0.018, PSNR 34.721 dB, SSIM 0.963; for FP-CIT, NRMSE 0.008, PSNR 41.889 dB, SSIM 0.982; and for FDG, NRMSE 0.013, PSNR 37.502 dB, SSIM 0.986. Mean reader quality scores for 5-minute DCLGAN images were high-4.48 (FBB), 4.50 (FDG), and 4.55 (FP-CIT)-with strong inter-reader agreement (κ=0.85, 0.83, 0.89, respectively). Quantitative agreement with full-time scans was excellent: ICCs for 5-minute images were 0.997 (FBB), 0.995 (FDG), and 0.996 (FP-CIT). Bland-Altman analyses showed minimal bias (mean bias -0.004 for FBB, 0.012 for FDG, -0.029 for FP-CIT) with narrow limits of agreement. Compared with 3-minute reconstructions, 5-minute DCLGAN images demonstrated significantly higher PSNR/SSIM and lower NRMSE (p<0.001), while maintaining or improving reader scores and quantitative agreement.
Conclusions:
Across FBB, FDG, and FP-CIT, DCLGAN enabled 5-minute neuro-PET acquisitions that appeared to maintain reader-rated quality and showed high agreement in SUVR/SBR values with full-time scans. These findings suggest that clinically practical scan-time reduction may be feasible while maintaining interpretability and quantitative integrity in this cohort.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography