Related Experiment Video
Updated: Jul 26, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
AI-based synthetic CT attenuation correction enables reliable quantitative SPECT in unilateral condylar hyperplasia
Anna Rebeka Kovács1, Enikő Fanni Juhász2, Péter Czina1
1Division of Nuclear Medicine and Translational Imaging, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, Debrecen, 4032, Hungary.
Purpose:
Unilateral condylar hyperplasia (UCH) is a rare mandibular growth disorder in which accurate assessment of condylar metabolic activity is essential for surgical decision-making. Quantitative 99mTc-methylene diphosphonate (MDP) SPECT/CT is commonly used for this purpose; however, CT-based attenuation correction (CTAC) increases radiation exposure and may be affected by registration errors. Artificial intelligence (AI)-generated synthetic CT (SyCT) has been proposed as a CT-independent alternative. This study aimed to evaluate the agreement between SyCT-based attenuation correction (SyCTAC) and conventional CTAC in quantitative SPECT imaging of UCH.
Methods:
This retrospective study included 14 patients with UCH who underwent 99mTc-MDP SPECT/CT. SPECT images were reconstructed with identical parameters using either CTAC or AI-generated SyCTAC. Spherical volumes of interest were placed over both mandibular condyles and the clivus, and maximum and mean standardized uptake values were measured. Relative uptake fractions normalized to the summed condylar activity were calculated for the affected side, while condylar uptake normalized to the clivus was evaluated for both sides. Agreement between CTAC- and SyCTAC-derived indices was assessed using Bland-Altman analysis and linear mixed-effects models.
Results:
Visual evaluation revealed no relevant differences in image quality between the two reconstructions. Relative uptake fractions normalized to the summed condylar activity showed good agreement between methods. Clivus-normalized ratios demonstrated a small positive bias.
Conclusion:
AI-generated SyCT provides attenuation correction comparable to CTAC for clinically relevant relative condylar uptake assessment in UCH, supporting its use as a low-radiation alternative for quantitative mandibular SPECT imaging.
More Related Videos
07:11Treatment of Facial Deformities using 3D Planning and Printing of Patient-Specific Implants
Published on: May 23, 2020
08:03Midface Hypoplasia and Cranial Base Morphology in Syndromic Craniosynostosis: A Comparative Analysis Study Using a Predictive Regression Model
Published on: November 4, 2025