A green analytical method for identification and quantification of carcinogenic impurity N-nitroso-desformyl
Veeraswami Boddu1, Manoj Kumar Mandapaka1
1Department of Chemistry, GITAM School of Science, GITAM Deemed to be University, Visakhapatnam, 530045, India. veeraswamiboddu@gmail.com.
Abstract:
Riociguat, a vasodilatory drug for treating pulmonary hypertension (PH), might generate a nitrosamine drug substance-related impurity (NDSRI), reported as N-nitroso-desformyl riociguat (NNDFR). NDSRIs are a class of nitrosamine impurities that are specific to each drug and are structurally related to the active pharmaceutical ingredient (API) either or both sharing a common molecular backbone but differing by specific functional groups. Such impurities have drawn growing regulatory attention due to their recognized genotoxic and carcinogenic potential, in which the identification and quantification in the product is mandatory. Thus, a sensitive and reliable Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry (UHPLC-MS/MS) method is developed employing a Shimpack-GIS CN column (150 mm × 4.6 mm × 3 µm) with a gradient of 0.1% formic acid in water, and 0.1% formic acid in methanol for chromatography separation, and in multiple reaction monitoring (MRM) mode in an electrospray ionization (ESI) environment. Optimized conditions focused on chromatographic selectivity, ionization efficiency, and matrix interference reduction. Method validation for the identification of NNDFR in the riociguat drug product confirmed that this method achieved baseline separation of NNDFR isomers with retention times of 10.037 (Isomer-1) and 10.579 (Isomer-2) minutes, prohibiting interferences from other compounds. Validation also confirmed excellent linearity (R2 > 0.99), precision (RSD < 1.3%), and accuracy (recoveries from 100.5% to 110.4%). The LOD and LOQ were determined to be 0.4 ppm and 1.22 ppm, respectively. A 24-hour stability study confirmed the analyte integrity and method robustness at various flow rates and column temperatures, and under various filtration conditions, ensuring consistent performance. This validated UHPLC-MS/MS method is robust, sensitive, and reliable for routinely quantifying NNDFR in riociguat drug products. Subsequently, the analytical method developed was assessed for environmental sustainability using established greenness assessment tools. The AGREE score was calculated to be 0.73, AGREEprep to be 0.69, and the BAGI value to be 70.0. These values reflected a favorable environmental profile, efficient sample preparation, and practical sustainability. Together, these metrics confirmed the method's suitability for both regulatory compliance and routine application in industrial quality control laboratories.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
12:15Quantification of three DNA Lesions by Mass Spectrometry and Assessment of Their Levels in Tissues of Mice Exposed to Ambient Fine Particulate Matter
Published on: May 29, 2019