Related Experiment Video
Updated: Apr 23, 2026

Deep-Learning Based Multi-Joint Synchronous Tracking for Objective Quantification of Hindlimb Locomotor Kinematics in Rats
Published on: April 3, 2026
Controlled comparative study of YOLOv8-Pose, YOLOv11-Pose, and Detectron2 for vertebrae detection and keypoint
Avinash Bansal1, Jan Kubíček1, Shalini Garg1
1Department of Cybernetics and Biomedical Engineering, VSB-Technical University of Ostrava, FEECS, Ostrava, Poruba, Czech Republic.
Abstract:
Accurate vertebrae detection with precise keypoint localization is essential for medical image analysis and clinical applications, such as spinal alignment assessment. This study presents a controlled, task-driven comparison of four pose-based deep learning models for vertebrae detection and keypoint estimation: YOLOv8n-Pose, YOLOv11n-Pose, and Detectron2 (Keypoint R-CNN) with ResNet-50 and ResNet-101 backbones. A single-class vertebrae dataset with bounding box annotations and four anatomically meaningful keypoints per vertebra was evaluated under consistent training settings. Performance was assessed in terms of keypoint localization accuracy, detection precision, inference speed, and vertebrae-specific prediction behavior, including detection completeness and duplicate detections, which are critical for clinical usability. Results show that YOLOv11n-Pose provides the best balance between keypoint accuracy and inference efficiency, while YOLOv8n-Pose achieves the fastest inference with competitive performance. Detectron2-based models exhibit lower keypoint accuracy, slower inference, and frequent duplicate predictions that obscure correct anatomical landmarks. Additional experiments indicate that larger YOLO variants (particularly YOLOv8l-Pose) improve accuracy, albeit at increased computational cost. Overall, the results demonstrate that model capacity or architectural recency alone does not guarantee superior performance in vertebrae keypoint detection, highlighting the importance of anatomy-aware model selection for spine imaging applications.
Related Concept Videos
Classification of Bones
Long and Short Bones
The appendicular skeleton, particularly the upper and lower limbs, is primarily made of long and short bones. The...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
General Structure of a Vertebra
Structural Classification of Joints
A fibrous joint is where the adjacent bones are united by fibrous connective...
Imaging Studies III: Computed Tomography