Related Experiment Video
Updated: Apr 23, 2026

Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
Validation and reliability of the Turkish version of the Lymphedema Symptom Intensity and Distress Survey-Lower Limb
Pınar Borman1, Aslıhan Aladağ Aydoğan2, Cansu Şahbaz Pirinççi3
1Department of Physical Medicine and Rehabilitation, Medical Faculty, Ankara Medipol University, Ankara, Turkey.
Abstract:
BackgroundEffective management of lower extremity lymphedema requires its recognition as a distinct clinical entity. This study aimed to evaluate the validity and reliability of the Turkish version of the Lymphedema Symptom Intensity and Distress Survey-Lower Limb (LSIDS-L), a tool designed to assess both the severity and distress of symptoms in patients with lower limb lymphedema.AimsTo evaluate the validity and reliability of the Turkish version of the Lymphedema Symptom Intensity and Distress Survey-Lower Limb (LSIDS-L) in patients with lower extremity lymphedema.Study designDiagnostic Accuracy Study.MethodsThe LSIDS-L was translated and culturally adapted into Turkish using the forward-backward translation method. The final version was administered to 155 patients alongside the Lymphoedema Quality of Life Questionnaire-Leg (LYMQOL-Leg). Reliability was assessed using a 7-days test-retest approach. Descriptive statistics were used for demographic data. Construct validity was evaluated using Spearman's rank correlation coefficient, while internal consistency and test-retest reliability were assessed via Cronbach's alpha and the intraclass correlation coefficient (ICC), respectively.ResultsThe questionnaire demonstrated excellent test-retest reliability with ICC1k = 0.9989 and r = 0.9970. Internal consistency was also high, with a Cronbach's alpha of 0.9180 and a standardized alpha of 0.9145, indicating strong coherence among items.ConclusionThe Turkish version of the LSIDS-L (LSIDS-L-TR) is a valid and reliable instrument for assessing symptom intensity and distress in patients with lower extremity lymphedema. It offers a comprehensive tool for use in both clinical practice and research settings.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure in the Leg
Preparation:

