Related Experiment Video
Updated: Apr 25, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Benchmarking PHITS for radiation dose assessment from fly ash-blended concrete using MCNP6 and ResRad-Build
Lam Duy Nhat1, Le Huu Loi2, Le Quang Vuong3
1Faculty of Physics and Engineering Physics, University of Science, Ho Chi Minh City, Viet Nam; Vietnam National University, Ho Chi Minh City, Viet Nam; Faculty of Physics, Ho Chi Minh City University of Education, Ho Chi Minh City, Viet Nam.
The PHITS Monte Carlo code accurately assesses indoor radiation exposure from fly ash concrete, showing minimal deviation compared to MCNP6 and ResRad-Build. This confirms PHITS as a reliable tool for evaluating building material radiation safety.
Area of Science:
- Radiation physics and shielding
- Nuclear engineering
- Environmental science
Background:
- Fly ash utilization in concrete can impact indoor radiation exposure.
- Accurate dosimetry is crucial for public health and safety.
- Benchmarking simulation tools is essential for reliable assessments.
Purpose of the Study:
- To evaluate indoor radiation exposure from fly ash-blended concrete using the PHITS Monte Carlo code.
- To benchmark PHITS performance against established codes (ResRad-Build, MCNP6).
- To validate PHITS for assessing radiation from building materials.
Main Methods:
- Modeling a reference room (RP-112 dimensions) with varying fly ash content (0-50%).
- Simulating radiation exposure using PHITS, ResRad-Build, and MCNP6 with input parameters including 226Ra, 232Th, and 40K activity concentrations.
- Systematic comparison of annual effective doses calculated by the different codes.
Main Results:
- PHITS calculated annual effective doses ranging from 0.378 to 0.489 mSv/y.
- Maximum relative deviations were 5.9% (vs. MCNP6) and 7.9% (vs. ResRad-Build).
- PHITS showed excellent agreement with reference dose estimates (max deviation 3.6%).
Conclusions:
- PHITS is a highly reliable and effective tool for indoor radiation exposure assessment.
- The code accurately simulates radiation from fly ash-blended concrete.
- PHITS provides a validated method for evaluating radiation safety of building materials.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Biological Effects of Radiation
Pozzolans
Fly ash is...
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...