Related Experiment Video
Updated: Apr 25, 2026

Detection of Neutralization-sensitive Epitopes in Antigens Displayed on Virus-Like Particle VLP-Based Vaccines Using a Capture Assay
Published on: February 10, 2022
A novel assay for quantifying Gn-LRP1-mediated neutralizing antibodies against severe fever with thrombocytopenia
Li-Fen Hu1,2,3,4, Meng-Ya Tu1, Ding-Ye Zhang1
1Department of Infectious Diseases, the First Affiliated Hospital of Anhui Medical University, Hefei, People's Republic of China.
Abstract:
Accurate and efficient determination of neutralizing antibody (nAb) is critical for assessing individual immune status of severe fever with thrombocytopenia syndrome (SFTS) and identifying key ecological reservoirs of the SFTS virus (SFTSV). However, conventional virus neutralization tests (cVNT) require live virus and are limited by their inability to support rapid, high-throughput screening. Here, we report a novel SFTSV virus neutralization test targeting the interaction between the SFTSV Gn protein and its receptor (LRP1). The test, which has been validated with SFTS patient plasma, achieves a sensitivity of 96.79% and a specificity of 100%. It also shows good correlation with cVNT, with an R² value of 0.8902 in head-to-head comparison. This platform offers a safe, rapid, and high-throughput alternative for large-scale population screening and the real-time monitoring of immune responses in SFTS patients.