Related Concept Videos

Focusing of Light in the Eye01:16

Focusing of Light in the Eye

6.1K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
6.1K
Angle Closure Glaucoma: Treatment01:28

Angle Closure Glaucoma: Treatment

1.6K
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A sequential strategy of upfront radiofrequency ablation followed by endoscopic papillectomy for complex ampullary tumors.

Frontiers in medicine·2026
Same author

A Rare Cause of Esophageal Submucosal Tumor.

Digestive diseases and sciences·2026
Same author

Clip-and-snare method with a pre-looping technique versus conventional method in the treatment of precancerous lesion and early gastric cancer: a retrospective study.

BMC gastroenterology·2024
Same author

Exosomal LINC00460/miR-503-5p/ANLN positive feedback loop aggravates pancreatic cancer progression through regulating T cell-mediated cytotoxicity and PD-1 checkpoint.

Cancer cell international·2022
Same author

Osteoblastic Swedish mutant APP expedites brain deficits by inducing endoplasmic reticulum stress-driven senescence.

Communications biology·2021
Same author

Lower limb kinetic comparisons between the chasse step and one step footwork during stroke play in table tennis.

PeerJ·2021

Related Experiment Video

Updated: Apr 25, 2026

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
05:46

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity

Published on: September 20, 2024

892

Off-axis aberration reduction in peripheral defocus spectacles using a moiré superlattice-based microlens array.

Honglin Chen, Shuqian Chen, Hao Zhang

    Applied Optics
    |April 24, 2026
    PubMed
    Summary

    This study introduces a novel microlens array design to reduce astigmatism and enhance peripheral retinal image quality. Simulations show improved optical performance compared to existing defocus incorporated multiple segments (DIMS) lenses.

    More Related Videos

    Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
    08:41

    Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution

    Published on: August 16, 2012

    11.0K
    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
    05:14

    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter

    Published on: September 16, 2025

    814

    Related Experiment Videos

    Last Updated: Apr 25, 2026

    Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
    05:46

    Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity

    Published on: September 20, 2024

    892
    Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
    08:41

    Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution

    Published on: August 16, 2012

    11.0K
    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
    05:14

    Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter

    Published on: September 16, 2025

    814

    Area of Science:

    • Ophthalmology and Optometry
    • Optical Engineering
    • Biomedical Engineering

    Background:

    • Peripheral retinal image quality is often degraded by off-axis aberrations.
    • Spectacle lens-induced aberrations are a key factor affecting visual performance.
    • Controlling these aberrations is crucial for improving vision correction.

    Purpose of the Study:

    • To propose and evaluate a novel microlens array design for reducing induced astigmatism.
    • To enhance peripheral retinal image quality in spectacle lenses.
    • To maintain therapeutic myopic defocus for myopia control.

    Main Methods:

    • A new microlens array design inspired by moiré superlattices was developed.
    • The Atchison eye model was used for optical simulations.
    • Performance was compared against Defocus Incorporated Multiple Segments (DIMS) lenses.

    Main Results:

    • The proposed design reduced maximum vectorial astigmatism (C') from -5.63D to -4.42D under static conditions.
    • Simulations showed an elevated Modulation Transfer Function Acutance (MTFA) value by 0.155 at 20 cy/mm during 15° eye rotation compared to DIMS lenses.
    • Central C' was optimized from -3.77D to -2.52D at 25° eye rotation.

    Conclusions:

    • The novel microlens array design shows potential for reducing astigmatism and improving peripheral image quality.
    • This design offers advantages over current DIMS lenses in specific optical metrics.
    • Further research may lead to improved spectacle lens designs for myopia management.