Related Experiment Video
Updated: Apr 25, 2026

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Automated Annuloplasty with VirtuoSEW® in microInvasive Mitral Valve Repair (μMVr)
Nermir Granov1, Farhad Bakhtiary2, Armin Šljivo1
1Clinic for Cardiovascular Surgery, Clinical Center of University of Sarajevo, Bolnička 25, 71000 Sarajevo, Bosnia and Herzegovina.
Abstract:
Background/Objectives: Totally endoscopic mitral valve repair reduces surgical trauma and accelerates recovery but can be technically challenging, particularly for precise annuloplasty suturing. The VirtuoSEW® (LSI Solutions, Victor, NY 14564m, USA) automated annular suturing system was developed to standardize and simplify suture placement. This study was an early evaluation of this technology's safety, efficacy, and feasibility in totally endoscopic microInvasive mitral valve repair (µMVr). Methods: We conducted a retrospective observational study of 20 patients with severe mitral valve disease of various etiologies. All patients underwent mitral valve repair using the VirtuoSEW® system for automated placement of annuloplasty sutures, combined with leaflet resection or chordal management as appropriate. Postoperative outcomes were assessed at one month using echocardiography and clinical evaluation. Perioperative and postoperative complications and early mortality were systematically recorded. Results: VirtuoSEW®-assisted mitral valve repair was safe and effective, achieving complete elimination of severe mitral regurgitation in all patients (N = 20, 100%). Annuloplasty rings included Physio-ring (N = 12, 60%), Memo 3D (N = 4, 20%), and Memo 4D (N = 4, 20%), combined with leaflet repair techniques: leaflet plication (N = 5, 25%), neochordae implantation (N = 7, 35%), sliding plasty (N = 2, 10%), commissural repair (N = 1, 5%), and hemibutterfly repair (N = 1, 5%). Concomitant procedures included: tricuspid valve repair (N = 1, 5%) and atrial septal defect closure (N = 1, 5%). Mitral annulus diameter decreased from 42.0 ± 5.3 mm to 34.2 ± 2.2 mm (p = 0.001). Mean total surgery, cardiopulmonary bypass, and aortic cross-clamp times were 170.3 ± 21.3, 143.4 ± 21.5, and 80.4 ± 7.9 min, respectively. ICU stay was 1.0 ± 0.2 days, with a hospital stay of 8.0 ± 1.9 days. No perioperative complications-including bleeding (N = 0, 0%), stroke (N = 0, 0%), infections (N = 0, 0%), or 30-day mortality (N = 0, 0%)-occurred. Conclusions: µMVR invasive mitral valve repair using the VirtuoSEW® system is safe, effective, and reproducible, as well as compatible with almost all repair techniques, providing complete restoration of valve competence with no early device-related complications. To our knowledge, this is the first clinical study reporting outcomes with this device, supporting its potential to streamline mitral repair and improve procedural efficiency.
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis I: Introduction
Mitral Regurgitation I: Introduction
Mitral Regurgitation III: Medical Management

