Related Experiment Video
Updated: Apr 26, 2026

A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Invasive Blood Pressure Monitoring Using Ultrasound-guided Artery Cannulation Through the Distal Radial Artery
Weijuan Zhu1, Ruoxing Chen1, Xiaoxiao Cheng2
1Department of Anesthesiology, the First Affiliated Hospital, Wenzhou Medical University, Zhejiang, China.
Ultrasound-guided radial artery cannulation in the anatomical snuffbox is a viable alternative for invasive blood pressure monitoring, showing comparable success rates to traditional methods. This distal transradial access offers a promising approach for critically ill patients.
Area of Science:
- Vascular Access
- Critical Care Medicine
- Ultrasound Guidance
Background:
- Invasive blood pressure monitoring is crucial for managing critically ill patients.
- Conventional radial and dorsalis pedis artery access sites have limitations.
- Distal transradial access is emerging as a less complicated and more comfortable alternative.
Purpose of the Study:
- To assess the feasibility of ultrasound-guided radial artery cannulation in the anatomical snuffbox.
- To compare this novel approach with conventional radial and dorsalis pedis artery cannulation.
Main Methods:
- A randomized controlled study involving 120 patients.
- Patients were randomized into three groups: anatomical snuffbox (Group A), radial artery (Group B), and dorsalis pedis artery (Group C).
- Coprimary outcomes included first-attempt success rate and puncture duration.
Main Results:
- First-attempt success rates were comparable across all groups (Group A: 75%, Group B: 72.5%, Group C: 52.5%).
- Puncture duration was significantly shorter in the conventional radial artery group (Group B) compared to both the anatomical snuffbox (Group A) and dorsalis pedis artery (Group C) groups.
- The anatomical snuffbox approach demonstrated comparable success rates to conventional methods.
Conclusions:
- Ultrasound-guided radial artery cannulation in the anatomical snuffbox is a clinically feasible option.
- This technique offers a viable alternative for invasive hemodynamic monitoring.
- It presents comparable success rates to traditional radial and dorsalis pedis artery cannulation.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: