Related Experiment Video
Updated: Apr 28, 2026

Field Postmortem Rabies Rapid Immunochromatographic Diagnostic Test for Resource-Limited Settings with Further Molecular Applications
Published on: June 29, 2020
Validation of the RapidChek® Listeria NextDayTM Plus Test System for Detection of Listeria spp. in Matrices: Hot
Verapaz Gonzalez1, Gregory Juck1, Juliet Wachira1
1Romer Labs, Inc., 130 Sandy Drive, Newark, DE 19713, USA.
Background:
Listeria monocytogenes presents a major challenge in the food industry. Routine monitoring is essential to ensure food safety in processing environments; therefore, rapid and reliable detection of Listeria is crucial for timely and effective intervention.
Objective:
To validate the RapidChek® Listeria NextDay™ Plus test system for the detection of L. monocytogenes, L. innocua, L. seeligeri, L. welshimeri, L. ivanovii, L. marthii, and L. grayi in selected foods including hot dogs, frozen cooked breaded chicken, and vanilla ice cream, and on environmental surfaces, including stainless steel, plastic, rubber, and painted concrete, using an unpaired study design.
Methods:
The method uses a proprietary enrichment medium, a 24 to 48 h enrichment at 30 ± 1°C and detects Listeria spp. on an immunochromatographic lateral flow device within 10 min. Listeria inoculated matrices were tested by the method, as well as the cultural reference method. The RapidChek method inclusivity was tested with 51 Listeria strains and its exclusivity using 30 non-target strains.
Results:
Probability of detection (POD) analysis indicated no significant differences between the candidate method and the cultural reference method in the number of positive test portions detected for hot dogs, frozen cooked breaded chicken, stainless steel, plastic, and painted concrete. For vanilla ice cream and rubber, the candidate method yielded a greater number of positive test portions, with significantly higher POD values at the 95% confidence interval. Following enrichment, the RapidChek assay detected all 51 Listeria strains evaluated and produced no false positives among the 30 non-target organisms tested.
Conclusion:
The candidate method performed as well as the reference method in the detection of Listeria spp. on environmental surfaces after 24 h of enrichment and in selected food matrices after 27 h of enrichment.
Highlights:
Enriching for 24-27 h yielded reliable presumptive results for Listeria spp.
More Related Videos
06:11Author Spotlight: Advancing Rapid Detection of Respiratory Pathogens Using Microfluidic Chip
Published on: March 29, 2024
12:50Colorimetric Paper-based Detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from Large Volumes of Agricultural Water
Published on: June 9, 2014